If the lamp fails to come on and the lamp monitor on the projector light is orange, you must replace the bulb.
A
For continued safety, replace with a lamp assembly of the same type.
Allow the projector to cool for at least 45 minutes before you open the lamp cover. The
inside of the projector can become very hot.
Do not drop the lamp module or touch the glass bulb
injury.
Follow these steps to replace the lamp assembly.
2. Disconnect the AC cord from the projector.
3. Remove screw with a screwdriver and disconnect the lamp cover.
4. Remove 2 screws with a screwdriver and pull out the lamp assembly by
grasping the handle.
5. Replace the lamp assembly.
6. Tighten 3 screws to secure the lamp cover to the lamp assembly.
7. Connect the detachable AC cord to the projector.
8. Reset the lamp replacement monitor timer. (See "LAMP AGE" section on page 46.)
NOTE:
Do not reset the LAMP REPLACEMENT MONITOR TIMER, except after the lamp replacement.
LAMP REPLACEMENT
The glass can shatter and cause
INDICATOR
LAMP
ASSEMBLY