Room Thermostat Control - Using The Leaving Water Temperature Home - Daikin Altherma EBLQ016CAV3 User Reference Manual

Altherma low temperature monobloc
Hide thumbs Also See for Altherma EBLQ016CAV3:
Table of Contents

Advertisement

Situation
18.0°C
19.0°C
Scheduled
Scheduled
Mon
17:00
Mon
17:00
18.0°C
20.0°C
Scheduled
Scheduled
Mon
17:00
Mon
17:20
20.0°C
21.0°C
Scheduled
Scheduled
Mon
17:20
Mon
17:20
To set the overrule period
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [7.2]:
> User settings > Temperature lock.
2 Select a value and press
▪ Permanent
▪ hours (2, 4, 6, 8)
Usage example: You have a party
If you are in the following situation:
▪ You are using the following room temperature schedule:
▪ 17:00 preset value (Comfort) = 20°C
▪ 23:00 preset value (Eco) = 18°C
▪ Tonight you have a party and you want to use the preset value
(Comfort) until 02:00.
Then you can do the following:
1 Set the overrule period (Temperature lock) to 6 hours.
2 At 20:00, go to the room temperature home page (Room).
3 Press
to select .
Result: The preset value (Comfort) will be used until 02:00.
After that, the schedule will be used again.
Usage example: You go away for a couple of hours
If you are in the following situation:
▪ You are using the following room temperature schedule:
▪ 08:00 preset value (Comfort) = 20°C
▪ 23:00 preset value (Eco) = 18°C
▪ At 14:00, you go away for 3 hours.
Then you can do the following:
1 Set the overrule period (Temperature lock) to 2 hours.
2 Go to the room temperature home page (Room).
3 Press
to select .
Result: For the next 2  hours, the room will NOT be heated to the
scheduled 20°C, but to the preset value (Eco = 18°C). After 2 hours,
the room will heat up again to the scheduled 20°C.
EBLQ+EDLQ011~016CAV3+W1 + EK(2)CB07CAV3 +
EKMBUHCA3V3+9W1
Daikin Altherma low temperature monobloc
4P522035-1 – 2018.01
Description
You temporarily overrule the
schedule.
Desired temperature = custom
temperature = 19°C.
At the next scheduled action
(17:00), the schedule will be
used again.
You change the mode from
scheduled to preset value
(Comfort (heating)).
Desired temperature = preset
value (Comfort (heating)) = 20°C.
After 2 hours, the schedule will
be used again (17:20 => 20°C).
Before you have changed the
mode from scheduled to preset
value, and now you temporarily
overrule the preset value.
Desired temperature = custom
temperature = 21°C.
After 2 hours, the schedule will
be used again (17:20 => 20°C).
:
Advantage:
You save energy because you do NOT heat the room unnecessary,
and by the time you come home the room is warm again.
4.4.6
Room thermostat control - Using the
leaving water temperature home pages
INFORMATION
The leaving water is the water that is sent to the heat
emitters. The desired leaving water temperature is set by
your installer in accordance with the heat emitter type.
Example: Underfloor heating is designed for lower leaving
water
temperature
than
convectors and/or fan coil units. You only have to adjust
leaving water temperature settings in case of problems.
Typical leaving water temperature home pages
Main zone:
User profile = Basic
Mon
15:20
LWT main
35°C
Desired temperature
Additional zone:
User profile = Basic
Mon
15:20
LWT add
45°C
Desired temperature
To read out the desired leaving water temperature
(main + additional)
Go to the leaving water temperature home page (LWT main or LWT
add).
To adjust/overrule the leaving water temperature
(NOT linked to room temperature setpoint)
INFORMATION
To see if the leaving water temperature setpoint is linked to
the room temperature setpoint, see
which temperature control you are using" on
To adjust the leaving water temperature (main)
1 Go to the main leaving water temperature home page (LWT
main).
2 Press
or
to adjust. Example:
INFORMATION
In case of weather dependency, an offset value can be
modified.
To adjust the leaving water temperature (additional)
1 Go to the additional leaving water temperature home page
(LWT add).
4 Operation
radiators
and
heat  pump
User profile = Detailed
Mon
15:20
35°C
LWT main
Desired temperature
Mon
17:30
User profile = Detailed
Mon
15:20
45°C
LWT add
Desired temperature
Mon
17:30
"4.4.3  Determining
page 7.
35°C 37°C
User reference guide