Configuring User Profile And Home; Preset Values And Schedules; Using Preset Values; Using And Programming Schedules - Daikin Altherma EBLQ016CAV3 User Reference Manual

Altherma low temperature monobloc
Hide thumbs Also See for Altherma EBLQ016CAV3:
Table of Contents

Advertisement

4 Operation
1 Go to [1]:
> Set time/date.
INFORMATION
Switch to Adv. end user to change daylight saving time and
12/24h notation.
To configure units of measurement
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [7.6]:
> User settings > Unit of measurement.
Possible units of measurement settings
Setting
Decimal point
Temperature
Produced energy
Flow
To configure the contrast of the user interface
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [7.1.1]:
> User settings > Display > Contrast.
To configure the backlit LCD time of the user interface
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [7.1.2]:
> User settings > Display > Backlit LCD time.
4.6.6
Configuring user profile and home pages
To set a user profile
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [7.1.3]:
> User settings > Display > User profile.
2 Select a user profile and press
Possible user profiles
If user profile = Detailed, you can see and do more on the home
pages.
User profile = Basic
Mon
15:20
Room
20.0°C
Actual temperature
To configure which home pages are made available to the
end user
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [7.1.4]:
> User settings > Display > Available home
pages.
Result: The home pages that are possible for your system
layout are listed.
2 Select a home page and press
3 Do one of the following:
▪ To display the home page, select Yes and press
▪ To hide the home page, select No and press
User reference guide
16
Possible units of measurement
▪ Dot
▪ Comma
▪ °C
▪ °F
▪ kWh
▪ MBtu
▪ l/min
▪ GPM
.
User profile = Detailed
Mon
15:20
20.0°C
Room
Actual temperature
Scheduled
Tue
17:30
.
.
.
4.7

Preset values and schedules

4.7.1

Using preset values

About preset values
You can define preset values for multiple controls. Preset values
make it easy to use the same value in many places (schedules and
room temperature home page ( and )). If you later want to change
the value, you only have to do it in one place.
To define preset values
1 Go to [7.4]:
> User settings > Preset values.
2 Select for which control you want to define a preset value.
Example: Room temperature.
3 Select a preset value and press
(heating).
4 Select a temperature and press
Possible preset values
Control
Preset value
Room
Comfort
temperature
Eco
LWT main
Comfort
Eco
Tank
Storage comfort
temperature
Storage eco
Reheat
Quiet level
Elec price
High
Medium
Low
Fuel price
4.7.2

Using and programming schedules

About schedules
Depending on your system layout and installer configuration,
schedules (predefined and/or user‑defined) for multiple controls may
be available.
You can:
▪ Select which schedules you currently want to use.
▪ Program your own schedules if the predefined schedules are not
satisfactory. The actions you can program are control specific.
EBLQ+EDLQ011~016CAV3+W1 + EK(2)CB07CAV3 +
Daikin Altherma low temperature monobloc
. Example: Comfort
.
Where used
▪ Room
temperature
schedules
▪ Room temperature home
page (
and
) if user
profile = Detailed
Main leaving water
temperature schedules
DHW tank temperature
schedule if DHW tank mode
is
▪ Scheduled
▪ Scheduled + reheat
DHW tank temperature
schedule if DHW tank mode
= Scheduled + reheat
Used when quiet mode is
set to On
Only when the Bivalent
setting is activated (installer
setting).
Only when the Bivalent
setting is activated (installer
setting).
EKMBUHCA3V3+9W1
4P522035-1 – 2018.01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents