Timer To Close; Standby Mode - Chamberlain HandyLift MyQ Installation And Operating Instructions Manual

Garage roller door opener
Table of Contents

Advertisement

18
TIMER TO CLOSE FEATURE (TTC)
Auto close is NOT recommended for households with young children.
TIMER TO CLOSE feature: (TTC) 10 to 180 seconds.
NOTE: Obstruction detection beams must be installed before TTC will operate.
The Timer to Close feature allows the door to automatically close after a specified time period. During the
OPEN door waiting period, the courtesy light will flash continuoulsy.
If the door encounters an obstruction while closing, the opener will
return to the OPEN position and the waiting period will begin again.
To activate the Timer to Close:
• Start with obstruction detection beams installed and the door fully
CLOSED
• Press and Hold both "P" and "DN" buttons for 3 seconds. When the
Courtesy light flashes "TWICE", release both buttons
• Press the "UP" for each 10 second interval required for
Timer to Close. A "BEEP" will register for each press. "DN" button
will reduce the count if needed.
• Press and release the "P" button to accept this setting
To deactivate the Timer to Close:
• Start with the door fully CLOSED
• Press and Hold both "P" and "DN" buttons for 3 seconds. When the
Courtesy light flashes "TWICE", release both buttons.
• Press and release the "P" button to accept this setting
The door may operate unexpectedly, therefore do not allow anything to obstruct the path of the
door.
STANDBY MODE (OPTIONAL)
19
The HandyLift MyQ has been factory set for low
standby mode (sub 1 watt usage).
This will deliver the lowest possible standby power. The
External Accessory Power is turned OFF in this mode,
so if this output is required, Normal Standby mode will
need to be activated (eg. for using an external receiver).
To activate NORMAL STANDBY mode.
• Turn the mains power OFF.
• Press and Hold both "UP" and "DN" buttons.
• Turn ON mains power while both buttons are
still pressed.
• Courtesy light comes ON, and after 5
seconds another 10 flashes. Release both
buttons.
To activate LOW STANDBY mode.
• Turn the mains power OFF.
• Press and Hold both "UP" and "DN" buttons.
• Turn ON mains power while both buttons are
still pressed.
• Courtesy light comes ON, and after 5
seconds another 1 flash. Release both
buttons.
ACTIVATE
TIMER TO
CLOSE
SET
TIME
ACCEPT
SETTING
NORMAL
STANDBY
DN
LOW
DN
STANDBY
18
Flash
x 2
1
3
DN
S
2
UP
P
3
2
1
DN
S
UP
P
Flash x 2
1
3
DN
S
2
P
UP
Flash x 10
1
3
S
2
UP
P
Flash x 1
1
3
S
2
P
UP

Advertisement