Manual Regeneration

Sometimes there is a need to regenerate the system, sooner than when the system calls for
it, usually referred to as manual regeneration. There may be an unexpected period of heavy
water usage.
To initiate a manual regeneration at the preset delayed regeneration time, press and
release "REGEN". The words "REGEN TODAY" will flash in left corner of display as it
scrolls through displays to indicate that the system will regenerate at the preset delayed
regeneration time. If you pressed the "REGEN" button in error, pressing the button
again will cancel the request.
To initiate a manual regeneration immediately, press and hold the "REGEN" button for five seconds. The system will begin to regen-
erate immediately. The request cannot be cancelled. You must cycle all the way through the cycles to make it stop. PLEASE NOTE:
This will reset the meter.
Note: If the salt tank does not contain salt, fill with salt and wait at least two hours before regenerating. If two regenerations
are desired within 24 hour period, press /release REGEN button. REGEN TODAY will flash on screen. Press and hold REGEN
button until valve initiates regeneration.
Regeneration Mode
Typically a system is set to regenerate at a time of low water usage. If there is a demand for water
when the system is regenerating, untreated water will be supplied.
When the system begins to regenerate, the display will change to include information about the
step of the regeneration process and the time remaining for that step to be completed (see figure
11). The system runs through the steps automatically and will reset itself to provide treated water
when the regeneration has been completed.
Normally it is not recommended to adjust the lengths of the cycle times. However, certain water conditions may dictate adjust-
ments. This should only be done from the recommendation of a water conditioning professional. The following chart shows
the upper and lower limits of each cycle.
[!J
EJEJEJ [!7
SOFTENING
TYPE
SET
[!J
EJEJEJ [!7
FILL
24
SET
LBS
[!J
EJEJEJ [!7
11
CYCLE TIME ADJUSTMENTS
Cycle Options
Service
Refill Brine Tank
Softening
Regenerant Draw UP
Backwash
Fast Rinse
STEP 1S
=  Up Arrow
STEP 1S – Press NEXT and  simultaneously for 3 seconds. If screen in Step 2S does
not appear in 5 seconds the lock on the valve is activated.
STEP 2S
STEP 2S – Select between softening or filtering. A flashing "SOFTENING" or
"FILTERING" will appear. Choose SOFTENING using  or  button. Factory setting is
Softening. Press NEXT to go to Step 3S. Press REGEN to exit Softener System Setup.
STEP 3S
STEP 3S – Select the time for the first cycle (which in this example is FILL) using the 
or  button. Press NEXT to go to Step 4S. Press REGEN to return to the previous step.
Units
NA
Lbs or Minutes
Mins
Mins
Mins
Mins

SOFTENER SETUP

=  Down Arrow
"REGEN TODAY"
EJEJEJ [!7
(shows time remaining in regen step
is 8 minutes, 22 seconds)
BACKWASH
Figure 11
Lower/Upper Limit
NA
0.1 -200 Lbs to 0.1-99 Min
1 to 480
1 to 180
1 to 120
1 to 120
CAPACITY REMAINING
320
GAL
[!J
Regeneration Step
8:22