Step 2: Connect POTS (PHONE)
If POTS cables are not available, use
procedure to create the POTS cables:
1. Trim the insulation for the subscriber POTS cables.
2. Refer to the
Figure 3
and connect the twisted-pair Tip (green)
and Ring (Red) to the RJ-11 connector using an RJ-11 crimper.
3. Insert the RJ-11 connector in the appropriate PHONE 1 or
PHONE 2 jack.
1 2 3 4
Figure 3. POTS (PHONE) Connection
Step 3: Connect Ethernet
The 424RG3 ONT supports four 1 Gigabit (10/100/1000Base-T)
connections (GE 1 to GE 4).
If Ethernet cables are not available, use the following procedure and
table to create the Ethernet cables:
NOTE
The Ethernet cables should be CAT 6 rated.
1. Trim the insulation for the subscriber Ethernet cable.
2. Connect the wires per the following table using an RJ-45
Crimper.
Ethernet RJ-45 Pin-out
Pin
Name
Description
1
TRD0+
Transmit/Receive Positive
2
TRD0-
Transmit/Receive Negative
3
TRD1+
Transmit/Receive Positive
4
TRD2+
Transmit/Receive Positive
5
TRD2-
Transmit/Receive Negative
6
TRD1-
Transmit/Receive Negative
7
TRD3+
Transmit/Receive Positive
8
TRD3-
Transmit/Receive Negative
3. Insert the CAT 6 rated cable in the appropriate GE 1 through GE
4 ports on the rear of the 424RG3 ONT.
Step 4: Connect Power
Plug the supplied 12 VDC Power Adapter into the
the rear of the chassis. Connect the AC plug to a standard 120 or 230
VAC outlet.
61287783F1-22A
Figure 3
and the following
1 = Not Connected
2 = Tip
3 = Ring
4 = Not connected
Color Code
White/
Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
12V
connection on
Step 5: Connect UPS (optional)
NOTICE
DO NOT connect the Power Adapter and an UPS at the same time as
this will cause damage to the 424RG3 ONT. The ONT can be powered
by either power source, but not both simultaneously.
The 424RG3 ONT can typically use an un-interruptible power supply
(UPS) if desired. Power is supplied to the 424RG3 ONT by a local
power source with battery backup that utilizes the AC power at the
customer premises. The UPS powers the 424RG3 ONT and functions
as a battery backup unit (BBU) supplying continuous 12 VDC. Refer
to the installation material that is provided with the UPS when
installing the BBU.
UPS Connector
Connect the UPS to the 8-pin MOLEX connector labeled "UPS"
located on the rear of the SFU ONT chassis.
MOLEX connector on the rear of the ONT.
Figure 4. 8-Pin Molex Connector
The UPS Power/Alarm Connections Table below defines each pin on
the connector.
NOTE
ADTRAN offers a UPS Cable assembly (P/N 1287402G1) for this
connector.
UPS Power/Alarm Table
The following table indicates which pin is associated with each alarm
provided through a UPS connection.
Pin-Out
Description
1
Power Input (+12 VDC)
2
UPS Status - On Battery
3
UPS Status - Battery Missing
4
Signal Return
5
Power 12 V Return
6
UPS Status - Replace Battery
7
UPS Status - Low Battery
8
No Connection
NOTE
If an UPS is being used and is disconnected, the 424RG3 ONT is not
protected from power outages, and will send a "Battery Missing"
alarm to the OLT.
Figure 4
illustrates the
Alarm
-
1
2
-
-
3
4
-
3