Commissioning/service reports
Control parameter report
DHW
Parameter
"Set DHW temperature"
"Min. DHW temperature"
"Max. DHW temperature"
"Hysteresis DHW temperature heat
pump"
"Hysteresis DHW temperature booster
heater"
"Start optimisation for DHW heating"
"Stop optimisation for DHW heating"
"Set DHW temperature 2"
"Temperature sensor at bottom of DHW
cylinder"
"Enable booster heaters for DHW heat-
ing"
"Enable electric heaters for DHW heat-
ing"
"Priority DHW heating with combi cylin-
der"
"Start attempts for DHW after high pres-
sure shutdown"
Solar
Parameter
"Type solar control unit"
"Max. collector temperature"
"Start hysteresis solar circuit pump"
"Stop hysteresis solar circuit pump"
"Flow rate solar circuit for calculating so-
lar yield"
"Display message incorrect circulation"
Electric booster heater
Parameter
"Enable instantaneous heating water
heater"
"Enable electric heaters for DHW heat-
ing"
"Enable instant. heating water heater for
central heating"
"Max. output instantaneous heating wa-
ter heater"
"Output for instant. heating water heater
at power-OFF"
"Dual mode temp instant. heating water
heater"
90
(cont.)
Code
Delivered condition Commission-
6000
500 (
6005
100 (
6006
600 (
6007
50 (
6008
100 (
6009
0
600A
0
600C
600 (
600E
0
6014
0
6015
1
6016
0
6017
1
Code
Delivered condition Commission-
7A00
0
7A01
1300 (
7A02
70 (
7A03
30 (
7A07
100 l/h
7A09
1
Code
Delivered condition Commission-
7900
1
7901
0
7902
0
7907
3
790A
0
790B
500 (
ing
50 °C)
10 °C)
60 °C)
5 K)
10 K)
60 °C)
ing
130 °C)
7 K)
3 K)
ing
50 °C)
Maintenance/
service
Maintenance/
service
Maintenance/
service