Fluke 377 Calibration Manual page 14

Clamp meter
Hide thumbs Also See for 377:
Table of Contents

Advertisement

377/377 FC/378/378 FC
Calibration Manual
Test (Switch Position)
K
iFlex Current Probe (with
ac voltage simulation)
K
iFlex Current Probe (with
[1]
50-turn coil)
10
Table 2. Performance Tests (cont.)
Calibrator
Output
1.05 mV @ 35 Hz
3 mV @ 100 Hz
15 mV @ 500 Hz
11.4 mV @ 20 Hz
58.5 mV @ 100 Hz
292.5 mV @ 500 Hz
28.8 mV @ 20 Hz
147 mV @ 100 Hz
720 mV @ 500 Hz
0.2 A @ 10 Hz
0.2 A @ 55 Hz
0.2 A @ 440 Hz
6 A @ 10 Hz
6 A @ 55 Hz
6 A @ 440 Hz
10 A @ 10 Hz
10 A @ 55 Hz
10 A @ 440 Hz
19 A @ 10 Hz
19 A @ 55 Hz
19 A @ 440 Hz
Readout Limit
Low
48 A
52 A
48 A
52 A
48 A
52 A
921 A
979 A
921 A
979 A
921 A
979 A
2423 A
2477 A
2423 A
2477 A
2423 A
2477 A
9.2 A
10.8 A
9.2 A
10.8 A
9.2 A
10.8 A
290.5 A
309.5 A
290.5 A
309.5 A
290.5 A
309.5 A
484.5 A
515.5 A
484.5 A
515.5 A
484.5 A
515.5 A
921 A
979 A
921 A
979 A
921 A
979 A
High

Advertisement

Table of Contents
loading

This manual is also suitable for:

377 fc378378 fc

Table of Contents