Fluke 377 Calibration Manual page 13

Clamp meter
Hide thumbs Also See for 377:
Table of Contents

Advertisement

Test (Switch Position)
N
DC Volts
D
Resistance
D
Capacitance
DC Amps (with 50-turn coil)
k
AC Amps (with 50-turn coil)
k
AC Current
Frequency
Table 2. Performance Tests (cont.)
Calibrator
Output
-570 V
-50 V
0 V
50 V
570 V
-950 V
950 V
0.000 mV
500 mV
-500 mV
0 Ω
570 Ω
5700 Ω
57 kΩ
10 μF
95 μF
950 μF
0.2 A
10 A
18 A
-18 A
-10 A
-0.2 A
0.2 A @ 45 Hz
9 A @ 66 Hz
19.5 A @ 60 Hz
3 A @ 45 Hz
9 A @ 66 Hz
19.5 A @ 440 Hz
Performance Tests
Readout Limit
Low
-576.2 V
-463.8 V
-51 V
-49 V
-0.5 V
0.5 V
49 V
51 V
463.8 V
576.2 V
-964.5 V
-935.5 V
935.5 V
964.5 V
-0.5 mV
0.5 mV
494.5 mV
505.5 mV
-505.5 mV
-494.5 mV
-0.5 Ω
0.5 Ω
563.8 Ω
576.2 Ω
5638 Ω
5672 Ω
56.38 kΩ
57.62 kΩ
9.5 μF
10.5 μF
93.65 μF
96.35 μF
936.5 μF
963.5 μF
9.3 A
10.7 A
440.5 A
459.5 A
955 A
995 A
-995 A
-955 A
-459.5 A
-440.5 A
-10.7 A
-9.3 A
9.3 A
10.7 A
440.5 A
459.5 A
955 A
995 A
44.275 Hz
45.725 Hz
65.17 Hz
66.83 Hz
437.3 Hz
442.7 Hz
Clamp Meter
High
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

377 fc378378 fc

Table of Contents