Certification
6.2 EMC and Environmental Type Tests
Environmental Type Tests
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-14
IEC 60068-2-30
IEC 60068-2-31
IEC 60068-2-78
IEC 60255-21-1
IEC 60255-21-2
IEC 60529
42
Test
Cold Temperature
Dry Heat
Change of Temperature
Humidity (Damp Heat, Cyclic)
Humidity (Damp
Heat, Steady State)
Description
Test Ad
Test Bd
Test Nb
Test Db
Free Fall
Test Cab
Vibration
Shock
Bump
Ingress Protection
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
5 Cycles, -40 to 85°
C (40 to 185° F)
95% (non-condensing)
55 °C (131 °F), 6 Cycles
Procedure 1, 2 falls from a
height of 250 mm (9.8 in)
10 days @ 55 °C (131 °F)
and 93% Relative Humidity
Level 2 (2 g @ 10 to 150 Hz)
Level 2 (30 g @ 11 mS)
Level 1 (10 g @ 16 mS)
IP3x