Certification
6.2 EMC and Environmental Type Tests
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-10
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 61000-4-18
IEC 61000-4-29
40
Test
Radiated RFI
Burst (Fast
Transient)
Surge
Induced
(Conducted) RFI
Magnetic Field
Damped
Oscillating
Magnetic Field
Voltage Dips
and Interrupts
Damped
Oscillatory
Mains Frequency
Voltage
Ripple on DC
Power Supply
Damped
Oscillatory Wave
Voltage Dips
and Interrupts
Description
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Enclosure Ports
Enclosure Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
DC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
DC Power Ports
Test Levels
Severity Levels
20 V/m
± 4 kV @ 2.5
and 5 kHz
± 4 kV @ 2.5
and 5 kHz
± 4 kV @ 5 kHz
± 4 kV Line-
to-Earth
± 2 kV Line-to-Line
± 2 kV Line-
to-Earth, ± 1
kV Line-to-Line
± 4 kV Line-
to-Earth
± 2 kV Line-to-Line
10 V
100 A/m for 3 min
1000 A/m for 3 s
100 A/m for
1 s (100 kHz
and 1 MHz)
30% for 1 period
60% for 50 periods
100% for 5 periods
100% for
50 periods
2.5 kV Common
1 kV Differential
Mode @ 1 MHz
30 V for 60 s
300 V for 1 s
10%
2.5 kV
Common Mode
1.0 kV
Differential Mode
2.5 kV
Common Mode
30% for 0.1 s
60% for 0.1 s
RUGGEDCOM RSG2488F
Installation Manual, 07/2021, C79000-G8976-1351-07
a
Note
4
3
4
3
5
5
 
3
4
3
3
 