Guía De Diagnóstico De Averías - Campbell Hausfeld IronForce IFN2190 Operating Instructions Manual

Framing nailer
Hide thumbs Also See for IronForce IFN2190:
Table of Contents

Advertisement

Operating Instructions
use. Always reconnect the air line
keep others at a safe distance from
BEFORE loading any fasteners. The
the work area in case of accidental
discharge of nails. Never point the
nailer could eject a fastener causing
nailer at anyone. Accidental
death or serious personal injury.
G Protect your eyes and ears. Wear
triggering of the nailer could result
in death or serious personal injury.
Z87 safety glasses,
G Do not drive a
with side shields.
nail on top of
Wear hearing
other nails. The
protection. Employers
nail could glance
and users are
and cause death
responsible for
or a serious
ensuring the user or anyone near
puncture wound.
the nailer wears this safety
G Do not operate
protection. Serious eye injury or
or allow anyone
permanent hearing loss could
else to operate
result.
the nailer if any
G Do not use a
warnings or
check valve or
warning labels
any other fitting
are not legible.
which allows air
Warnings or warning labels are located
to remain in the
on the nailer magazine and body.
nailer. Death or
G Never leave the nailer unattended or
serious personal injury could occur.
connected to an air compressor when
G Never place
not in use. Serious personal injury
hands or any
can occur if someone picks up and
other body parts
uses the nailer without knowing the
in the nail
correct way to operate the nailer.
discharge area
G Do not drop or throw the tool.
of the nailer.
Dropping or throwing the tool can
The nailer might
result in damage that will make the
eject a fastener and could result in
tool unusable or unsafe. If the tool
death or serious personal injury.
has been dropped or thrown,
G Never carry the
examine the tool closely for bent,
nailer by the air
cracked or broken parts and air
hose or pull the
leaks. STOP and repair before using
hose to move the
or serious injury could occur.
nailer or a
compressor. Keep
CAUTION
!
hoses away from
heat, oil and sharp edges. Replace
hazardous situation which, if not
avoided, MAY result in minor or
any hose that is damaged, weak or
moderate injury.
worn. Personal injury or tool
G Do not modify or alter the nailer or
damage could occur.
G Always assume the nailer contains
any nailer parts. Do not use the nailer
if any shields or guards are removed
nails. Never use the nailer as a toy.
or altered. Do not use the nailer as a
Do not engage in horseplay. Always
Nailer Components And Specifications
IFN2190
IFN3490
• REQUIRES (SCFM with 16
nails per minute @ 90 psi)
4.1
• AIR INLET
1/4" NPT
1/4" NPT
1
• NAIL LENGTH RANGE
2" to 3
"
2" to 3
2
• NAIL SHANK RANGE
0.113" to 0.131"
0.113" to 0.131"
• MAGAZINE CAPACITY
60-75
75-105
• WEIGHT
8 lbs. 5 oz.
8 lbs. 11 oz.
• LENGTH
19.5"
19.75"
• HEIGHT
15"
• MAXIMUM PRESSURE
120 psi
120 psi
• PRESSURE RANGE
70 - 120 psi
70 - 120 psi
Model IFN3490 and IFN2190
hammer. Personal injury or tool
dam.occur.
G Avoid long extended periods of work
with the nailer. Stop using the nailer
if you feel pain in hands or arms.
G Always check
that the
Work Contact
Element
(WCE) is
operating
properly. A
nail could
accidentally
WARNING
!
be driven if
the WCE is not working properly.
Personal injury may occur (See
"Checking the Work Contact
Element" Section).
G Disconnect air supply and release
tension from the pusher before
attempting to clear jams because
fasteners can be ejected from the
front of the nailer. Personal injury
may occur.
NOTICE
information, that if not followed, may
cause damage to equipment.
G Avoid using the nailer when the
magazine is empty. Accelerated
wear on the nailer may occur.
G Clean and check all air supply hoses
and fittings before connecting the
nailer to an air supply. Replace any
damaged or worn hoses or fittings.
Caution indicates a
Tool performance or durability may
potentially
be reduced.
G Air compressors providing air to the
nailer should follow the
requirements established by the
American National Standards
Institute Standard B19.3-1991;
Safety Standard for Compressors for
Process Industries. Contact your air
Adjustable Direction
Exhaust Deflector
Threaded Hole/Tool
Balancer (M8 x 1.25)
Nail Loading Area
Single Cycle
4.1
Trigger
1
"
2
15"
Warning Labels
Work
Contact
Nail Discharge
Element
Area
www.chpower.com
2
Manual de Instrucciones
Guía de Diagnóstico de Averías
ADVERTENCIA
!
debe hacer un técnico calificado personal de un centro autorizado de servicio.
Problema
Hay una fuga de aire en el
área de la válvula del gatillo
Hay una fuga de aire entre la
cubierta y la boquilla
Hay una fuga de aire entre la
cubierta y la tapa
La clavadora deja de clavar un
clavo
Notice indicates
important
La clavadora funciona
lentamente o pierde su
potencia
Hay clavos atascados en la
clavadora
Magazine
Hay una fuga de aire en el
vástago de la válvula del gatillo
Deje de usar la clavadora inmediatamente si alguno de los si guientes problemas ocurre.
repuestos. Podría resultado le heridas graves. Cualquier reparación o reemplazo de piezas los
Causa
Solución
Los anillos en O de la cubierta de la válvula del
Debe reemplazar los anillos en O & chequear el
gatillo están dañados
funcionamiento del elemento de funcionamiento al contacto
Los tornillos de la cubierta están flojos
Debe apretar los tornillos
Los anillos en O están dañados
Debe reemplazar los anillos en O
La defensa está dañada
Debe reemplazar la defensa
Los tornillos están flojos
Debe apretar los tornillos
El empaque está dañado
Debe reemplazar el empaque
La defensa está desgastada
Debe reemplazar la defensa
La boquilla está sucia
Debe limpiar el canal del sistema de impulso
La suciedad o daños evitan el desplazamiento
Debe limpiar el cargador
libre de los clavos o el mecanismo de impulso en
el cargador
El resorte del mecanismo de impulso está dañado
Debe reemplazar el resorte
El flujo de aire hacia la clavadora es inadecuado
Chequée las conexiones, la manguera o el compresor
El anillo en O del pistón está desgastado o le
Debe reemplazar los anillos en O. Lubríquelos.
falta lubricación
Los anillos en O de la válvula del gatillo están
Debe reemplazar los anillos en O
dañados
Hay fugas de aire
Debe apretar los tornillos y las conexiones
Hay una fuga en el empaque de la tapa
Debe reemplazar el empaque
La clavadora no está bien lubricada
Necesita lubricar la clavador
El resorte de la tapa del cilindro está roto
Debe reemplazar el resorte
El orificio de salida de la tapa está obstruído
Debe reemplazar las partes internas dañadas
La guía del mecanismo de impulso está desgastada
Debe reemplazar la guía
Los clavos no son del tamaño adecuado.
Debe usar los clavos recomendados para esta clavadora
Los clavos están doblados
Reemplácelos con clavos en buenas condiciones
Los tornillos del cargador o de la boquilla están flojos
Debe apretar los tornillos
Debe reemplazar el mecanismo de impulse de clavos
El mecanismo de impulso está dañado
Los anillos en O o los sellos están dañados
Debe reemplazar los anillos en O o los sellos
7-Sp