11. Technical data

Ambient conditions
Storage temperature:
Ambient temperature:
Relative humidity:
Sauna control unit
Dimensions:
Switching voltage:
Frequency:
Contact rating / heater AC 1:
Switching current / heater AC 1:
Contact rating of evaporator AC 1:
Switching current of evaporator AC 1:
Rated voltage
Min./max. input power:
Protection type (protected against splashing water):
Temperature setting range:
Light
Contact rating:
Fuse:
Thermal safety
Heater sensor with excess temperature fuse (139 °C shut-off temperature)
Automatically switches off after 6 hrs. (heating period limit)
Single sensor system with temperature sensor above the heater
Connection cables
Sensor wires:
Light wire:
Temperature resistance
Heater, light and sensor wires
Power supply cable
WORLD OF WELLNESS
p. 22/22
-25°C to +70°C
-10°C to +40°C
max. 95%
250 x 200 x 80 mm
230 V
50 Hz
1 x 3.6 kW
16 A
1.2 kW
5.4 A
230 V
7/12 VA
IPX4
+40°C to +125°C
100 W
1A T
min. 0.5 mm²
min. 1.5 mm²
min. 150°C
min. 90°C