Instructions for installation and use

4.4. Installing the bench sensor

Refer to Fig. 5 (page 13).
ATTENTION!
Sources of interference can have a negative effect on signal transmission
● Lay the heater sensor wires separately from other mains wires and control
wires.
● Protect wires with only one layer of insulation by using a pipe (double insulation).
1. Lay the two 2-pin bench sensor wires 3 in the wall of the sauna room, lead
them to the location where the bench sensor is installed, and secure the
bench sensor wires using wire clips.
2. Install the bench sensor on the rear of the cabin using the two included
wood screws 2 (16 mm). The optimum position is opposite the sauna heater.
Maintain a distance of 15 cm to the sauna cabin roof.
Fig. 5
2
1
3
WORLD OF WELLNESS
Bench sensor
1
Wood screws (16 mm)
2
Bench sensor wires
3
p. 13/22