Carrier WeatherExpert 48LC Series Installation Instructions Manual page 58

Single package rooftop gas heat/electric cooling unit with puron (r-410a) refrigerant
Table of Contents

Advertisement

Motor
Motor
Voltage
Option
P/N
208/230V HD56FE653 HK30WA371 131L9796
STD
460V
HD56FE653 HK30WA377 131L9864
575V
HD56FE577 HK30WA382 131N0225
208/230V HD60FE656 HK30WA372 131L9797
MID
460V
HD60FE656 HK30WA378 131L9865
575V
HD58FE577 HK30WA383 131N0227
208/230V HD60FK658 HK30WA372 131L9797
HIGH
460V
HD60FK658 HK30WA379 131L9866
575V
HD60FE576 HK30WA387 134F0217
START
DELAY
(SEC)
Motor
Voltage
1-71
Option
208/230V
2.0
STD
460V
2.0
575V
2.0
208/230V
2.0
MID
460V
2.0
575V
2.0
208/230V
2.0
HIGH
460V
2.0
575V
2.0
RAMP UP
TIME
(SEC)
Motor
Voltage
3-41
Option
208/230V
10.00
STD
460V
10.00
575V
10.00
208/230V
10.00
MID
460V
10.00
575V
10.00
208/230V
10.00
HIGH
460V
10.00
575V
10.00
TERMINAL 53
VOLTAGE
Motor
Voltage
Option
208/230V
STD
460V
575V
208/230V
MID
460V
575V
208/230V
HIGH
460V
575V
Table 28 — VFD Unit Parameters - 48LC 12 Units
REGIONAL
VFD
VFD
Carrier
Mfr
P/N
P/N
MIN
SPEED
MOTOR
FLYING
FOR
THERMAL
START
FUNCTION
PROTECTION
(Hz)
1-73
1-82
1-90
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
[1]
1.0
[4]
RAMP DOWN
CURRENT
TIME
LIMIT
(SEC)
3-42
4-18
10.00
100%
10.00
100%
10.00
100%
10.00
100%
10.00
100%
10.00
100%
10.00
100%
10.00
100%
10.00
100%
TERMINAL 53
LOW
HIGH
VOLTAGE
6-10
6-11
2
[10]
2
[10]
2
[10]
2
[10]
2
[10]
2
[10]
2
[10]
2
[10]
2
[10]
GRID
MOTOR
SETTINGS
TYPE
POWER
VOLTAGE
0-03
0-06
1-20
[1]
[102]
[10]
[1]
[122]
[10]
[1]
[132]
[11]
[1]
[102]
[11]
[1]
[122]
[11]
[1]
[132]
[11]
[1]
[102]
[13]
[1]
[122]
[13]
[1]
[132]
[13]
3-10 [0] 3-10 [1] 3-10 [2] 3-10 [3] 3-10 [4] 3-10 [5] 3-10 [6] 3-10 [7]
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
0%
66.50% 66.50%
TERMINAL 18
DIGITAL
INPUT
5-10
[8]
[8]
[8]
[8]
[8]
[8]
[8]
[8]
[8]
TERMINAL 53
TERMINAL 53
LOW
REFERENCE
REFERENCE
6-14
0
0
0
0
0
0
0
0
0
58
MOTOR
MOTOR
CURRENT
FREQUENCY
(MUST-HOLD
(Hz)
1-22
1-23
230
60
460
60
575
60
230
60
460
60
575
60
230
60
460
60
575
60
PRESET
REFERENCE
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
TERMINAL 19
TERMINAL 27
DIGITAL
DIGITAL
INPUT
INPUT
5-11
5-12
[16]
[17]
[16]
[17]
[16]
[17]
[16]
[17]
[16]
[17]
[16]
[17]
[16]
[17]
[16]
[17]
[16]
[17]
RESET
HIGH
MODE
6-15
14-20
[60]
[3]
[60]
[3]
[60]
[3]
[60]
[3]
[60]
[3]
[60]
[3]
[60]
[3]
[60]
[3]
[60]
[3]
MOTOR
MOTOR
NOMINAL
SPEED
AMPS)
(RPM)
1-24
1-25
7.9
1680
3.6
1680
3.8
1680
11.7
1750
5.4
1750
4.9
1710
13.6
1745
6.8
1745
6.0
1745
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
TERMINAL 29
DIGITAL
INPUT
5-13
[18]
[18]
[18]
[18]
[18]
[18]
[18]
[18]
[18]
AUTO.
RFI
RESTART
FILTER
TIME (S)
14-21
14-50
600
[0]
600
[0]
600
[0]
600
[0]
600
[0]
600
[0]
600
[0]
600
[0]
600
[0]