Lincoln Electric Air Vantage 600X-I Operator's Manual page 9

Table of Contents

Advertisement

AIR VANTAGE
600X-I
®
GENERAL DESCRIPTION
The Air Vantage
®
600X-I is a diesel engine-driven welding power
source. The machine uses a brush type alternating current
generator for DC multi-purpose welding, for 120/240 VAC single
phase and 240 VAC three phase auxiliary standby power. The
welding control system uses state of the art Chopper
Technology
®
. The machine also integrates a belt-driven 60 CFM
rotary screw compressor.
The machine has been equipped with CrossLinc
provide weld cable communication for voltage control at the arc
without the need for a control cable.
TECHNICAL SPECIFICATIONS
INPUT - DIESEL ENGINE
Make /Model
(K4394-2)
Deutz
®
TD2.9L4
EPA Tier 4i
Speed (RPM)
High Idle 1800
Low Idle 1525
Full Load
Starting System
12 VDC Battery and Starter
with Automatic Glow Plugs
Battery Size
BCI Group Size 34
800 Cold Crank Amps
RATED OUTPUT @ 104°F(40°C) - WELDER
Duty Cycle
Welding Output
575 Amps
100%
(DC multi-purpose)
600 Amps
60%
(DC multi-purpose)
Compressor Model
Description
Belt-Drive Rotary
VMAC® S700162
Screw
IEC 60974-1; IP23 Rated
Technology to
®
Description
4 Cylinder 65.7 HP (49 kW)
Turbocharged Water Cooled
Diesel Engine
Displacement
178 cu. in. (2.9L)
Bore x Stroke
3.62" x 4.33"
92mm x 110mm
Capacities
Fuel: 25 US gal. (94.6L)
Oil: 2.25 US gal. (8.5L)
Cooling System: 2.5 US gal.
(9.5L)
Volts at Rated Amps
43 Volts
40 Volts
COMPRESSOR SPECIFICATIONS
Maximum System
Pressure
High Idle:
60 cfm @ 100 psi
(1.7 cmm @ 6.9 bar)
OUTPUT @ 104°F(40°C) - WELD ER AND GENERATOR
Welding Mode
CC-Stick
Downhill Pipe (CC)
Touch Start TIG
CV-Wire
Arc Gouging
Open Circuit Voltage
60V Avg @ 1800 RPM
70V Peak @ 1800 RPM
Auxiliary Power
120/240 VAC
7,800 Watts, 60 Hz., Single Phase
20,000 Watts, 60 Hz., Three Phase
RECEPTACLES
Receptacle
120 VAC Duplex (5-20R) GFCI Protected
240 VAC Three Phase (15-50R)
120 VAC IEC 60309 Yellow 2P+Ground
240 VAC IEC 60309 Blue 2P+Ground
PHYSICAL DIMENSIONS
Height
(2)
Width
(3)
Depth
Weight
(4)
(1) Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When weld-
ing, available auxiliary power will be reduced.
(2) Top of Enclosure. Add 16.1" (409 mm) for exhaust and air cleaner.
(3) Includes Door. Base is 31.6" (803 mm) wide.
(4) Approximate weight less fuel.
Compressor Protection
Capacities
Safety Relief Valve:
200 psi (13.8 bar)
1.1 US gal. (4.0L)
High Temperature
Automatic Shutdown:
290°F (143°C)
A-1
INSTALLATION
Output Range
30-600 Amps
40-350 Amps
20-350 Amps
10-45 Volts
60-600 Amps
(1)
Circuit Breaker
20 Amps
50 Amps
15 Amps
15 Amps
42.0 in. (1066.8 mm)
32.9 in. (835.7 mm)
69.0 in. (1753 mm)
1737 lbs. (787 kg)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents