AIR VANTAGE
600X-I
®
TEST MODES FOR GRID LOAD TESTING
The left display will show "tESt" and "LoAd" alternately at 0.5
second intervals. The right display will show "CC" (mode
200)(Figure B.14), "CV" (mode 201)(Figure B.15) or "OFF"
(normal operation)(Figure B.16). This setting is not remembered
between machine power cycles and will default to OFF at each
power on. Moving the position of the weld mode selector switch
will reset the setting back to OFF.
FIGURE B.14
Test
FIGURE B.15
Load
FIGURE B.16
Test
RESET BACK TO DEFAULT SETTINGS
Pressing and holding the hidden reset push button for 5 seconds
will cause certain stored values to be reset to defaults. The stored
hot start values will return to a default setting of 5 on the display
(0 at the attribute). The work point values will all be reset to the
minimum from the weld table for each respective weld mode. The
alternate CV mode selection will revert back to the Flux-Cored Arc
Welding-Self Shielding (FCAW-SS) setting. The remote pot
connector choice will revert back to the 12-pin connector. When
the reset occurs, the left display will show " deF", and the right
display will show "AuLt" for 3 seconds until the machine exits the
menu system.
CC
CV
OFF
B-11
OPERATION