Installation
Safety distances to the sides and
back of the appliance
The SmartLine appliance should
preferably be installed with plenty of
space on the right and left.
The minimum distance  specified
below must be observed between the
rear of the SmartLine element and a tall
unit or room wall.
The minimum distance ,  specified
below must be adhered to between one
side of the SmartLine element (right or
left) and a tall unit or room wall. A
minimum distance of 300 mm must be
observed on the opposite side.
Minimum horizontal distance from the
back edge of the appliance to a
combustible surface:
50 mm
 Minimum distance on the right side
between the worktop cut-out and the
closest adjacent piece of furniture (e.g.
tall unit) or a room wall:
50 mm.
 Minimum distance on the left side
between the worktop cut-out and the
closest adjacent piece of furniture (e.g.
tall unit) or a room wall:
50 mm.
52
Minimum safety distance underneath
the SmartLine appliance
To ensure proper ventilation of the
SmartLine appliance, a minimum safety
distance is required between the
SmartLine appliance and an oven,
interim shelf or drawer.
The minimum safety distance from the
lower edge of the SmartLine appliance
to
– the top edge of an oven: 15 mm
– the top edge of an interim shelf:
15 mm
– the top edge of a drawer: 5 mm
– the base of a drawer: 75 mm
Interim shelf
It is not necessary to fit an interim shelf
underneath the SmartLine appliance,
but one may be fitted if you wish.
Leave a gap of 10 mm at the back of
the shelf to accommodate the mains
connection cable. We recommend a
gap at the front of the SmartLine
appliance of 20 mm to ensure good
ventilation.