Correction Factors - Beko DRYPOINT RS 25-1010 HP50 Instructions For Installation And Operation Manual

High pressure compressed air refrigeration dryer
Table of Contents

Advertisement

Installation
8.3

Correction factors

Correction factor for operating pressure changes:
Inlet air pressure
Factor (F1)
Correction factor for ambient temperature changes (Air-Cooled):
Ambient temperature
Factor (F2)
Correction factor for inlet air temperature changes:
Air temperature
Factor (F3)
Correction factor for DewPoint changes:
DewPoint
ºC
Factor (F4)
Calculation of the actual air throughput:
Actual air throughput = air throughput acc. to planning x factor (F1) x factor (F2) x factor (F3) x factor (F4)
Example:
The DRYPOINT RS 180 HP50 has a planned nominal capacity of 180 m³/h. The highest achievable air
mass under the following operating conditions is:
Air inlet pressure = 35 bar(g)
Ambient temperature = 35°C
Air inlet temperature = 45°C
Pressure dew point = 10°C
Every function parameter corresponds to a numerical factor which, multiplied by the planned nominal capacity,
determines the following:
144 m³/h is the maximum flow rate of the dryer under the aforementioned operating conditions.
Selection of the best suitable model in accordance with the operating conditions:
Air throughput acc. to planning =
Example:
The following operating parameters are known:
Required air mass = 200 m
Air inlet pressure = 35 bar(g)
Ambient temperature = 35°C
Air inlet temperature = 45°C
Pressure dew point = 10°C
To find out the correct dryer version, the required air mass must be divided by the correction factors of the
parameters indicated above:
Air throughput acc. to planning =
The suitable model for these requirements is DRYPOINT RS 320 HP50 (with a spec. nominal capacity of 315 m³/h).
16
bar(g)
15
0.57
ºC
25
1.00
ºC
25
1.20
3
1.00
Actual air throughput = 180 x 0.94 x 0.90 x 0.69 x 1.37 = 144 m³/h
Factor (F1) x Factor (F2) x Factor (F3) x Factor (F4)
3
/h
0.94 x 0.90 x 0.69 x 1.37
20
25
30
0.70
0.80
0.88
30
35
0.96
0.90
30
35
40
1.12
1.00
0.83
5
1.09
 Factor (F1) = 0.94
 Factor (F2) = 0.90
 Factor (F3) = 0.69
 Factor (F4) = 1.37
Requ. air throughput
 Factor (F1) = 0.94
 Factor (F2) = 0.90
 Factor (F3) = 0.69
 Factor (F4) = 1.37
200
= 250 m³/h
35
40
0.94
1.00
40
45
0.82
0.72
45
50
55
0.69
0.59
0.50
7
1.19
DRYPOINT® RS 25-1010 HP50
45
50
1.05
1.10
50
0.60
60
65
0.44
0.39
10
1.37