1. Angle-indicator mount
2. Edge of the magnet mated
with the edge of the
bedknife
4.
Place the angle indicator on the mount as shown
in
Figure
28.
Note:
This is the angle that your grinder
produces, and should be within 2 degrees of the
recommended top grind angle.
Servicing the Bedbar
Removing the Bedbar
1.
Turn the bedbar-adjuster screws
counterclockwise to back the bedknife
away from the reel
1. Bedbar-adjusting screw
2. Spring-tension nut
2.
Back out the spring-tension nut until the washer
is no longer tensioned against the bedbar
(Figure
29).
Figure 28
3. Bedknife
4. Angle indicator
(Figure
29).
Figure 29
3. Bedbar
4. Washer
3.
On each side of the machine, loosen the locknut
securing the bedbar bolt
1. Bedbar bolt
g034114
4.
Remove each bedbar bolt, allowing the bedbar
to be pulled downward and removed from
machine bolt
washers and 1 stamped steel washer on each
end of the bedbar
1. Bedbar bolt
2. Nut
Assembling the Bedbar
1.
Install the bedbar, positioning the mounting ears
between the washer and the bedbar adjuster.
2.
Secure the bedbar to each side plate with the
bedbar bolts (nuts on bolts) and 6 washers.
3.
Position a nylon washer on each side of the
side-plate boss.
4.
Place a steel washer outside each of the nylon
g016647
washers
Note:
Torque the bedbar bolts to 37 to 45 N∙m
(27 to 33 ft-lb). Tighten the locknuts until the
outside steel washer stops rotating and end play
is removed, but do not overtighten or deflect
the side plates. The washers on the inside may
have a gap.
18
(Figure
Figure 30
2. Locknut
(Figure
30). Account for 2 nylon
(Figure
31).
Figure 31
3. Steel washer
4. Nylon washer
(Figure
31).
30).
g003334
g003335