Getcommunicationscheme - Siemens SIMATIC RF310M Function Manual

Mobile readers
Hide thumbs Also See for SIMATIC RF310M:
Table of Contents

Advertisement

Parameters
Return value(s)
None
Exceptions
RfReaderApiException
Note
The modulation scheme defines the data exchange rate between reader and tag. The
possible modulation scheme depends on the used radio profile ETSI or FCC.
Valid ranges for the RF680M are:
FCC :
2 = DSB-ASK 40kHz- FM0 40kHz
4 = DSB-ASK 160kHz- FM0 400kHz
6 = PR-ASK
8 = PR-ASK
ETSI:
2 = DSB-ASK 40kHz- FM0 40kHz
5 = DSB-ASK
6 = PR-ASK
7 = PR-ASK
Version information
Supported in RFID Reader Interface since V1.3
3.4.10

GetCommunicationScheme

GetCommunicationSchema( ) : uint
Parameters
None
Return value(s)
This functions returns the current communication scheme of the reader.
Mobile Readers
Function Manual, 12/2010, J31069-D0198-U001-A2-7618
communicationScheme
The profile ID of the modulation schema.
40kHz - M4 250kHz
40kHz - M2 250kHz
40kHz - M2 160kHz
40kHz - M4 250kHz
40kHz - M4 300kHz
Error while starting the communication with the reader. Check
the Error member for more information.
RFID Reader Interface Reference
3.4 IRfReaderApi
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf610mSimatic rf680m

Table of Contents