3.4.6
SetAirProtocol
SetAirProtocol( protocolName : string, initialQ : int) : void
Parameters
● protocolName
● initialQ
Return value(s)
None
Exceptions
RfReaderApiException
Note
This method is an alternate choice instead of the AirProtocol property described earlier. In
contrast to the property, it allows an additional parameter (initialQ) to be specified for the
EPC Class1 Gen2 protocol.
Version information
Supported in RFID Reader Interface: since V1.0
3.4.7
SetAntennaPower
SetAntennaPower (power : uint) : void
Parameters
Return value(s)
None
Exceptions
RfReaderApiException
Mobile Readers
Function Manual, 12/2010, J31069-D0198-U001-A2-7618
A string specifying the air protocol to be set.
An integer value that denotes the initialQ value used for collision detection with EPC
Class1 Gen 2 tags.
This parameter is ignored if an air protocol other than 'EPCC1G2' is specified.
Error while communicating with the reader service. Check the Error
member for more information.
power
•
The antenna power in mW.
Error while starting the communication with the reader. Check
the Error member for more information.
RFID Reader Interface Reference
3.4 IRfReaderApi
47