Removal Of Fan Motor - Daikin 2MXS18GVJU Service Manual

Removal procedure, 7.1/8.0 kw class, 18000 btu/h class, outdoor unit, inverter, multi type, heat pump
Hide thumbs Also See for 2MXS18GVJU:
Table of Contents

Advertisement

Si12-994

6. Removal of Fan Motor

Procedure
Step
1
Remove the nut and
remove the outdoor fan.
2
Remove the 2 screws of
the fan motor mount.
3
Disconnect the fan motor
lead wire by releasing the
2 clamps fixing the wire.
Remove the 4 screws to
remove the fan motor.
Removal Procedure
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Fan
motor
mount
(Backside)
Fan motor
Preparation
(R10362)
(R10363)
Clamp
(R5567)
Removal of Fan Motor
Points
Disconnect the connector for
the fan motor.
Nut size : M6
10 mm
(R12236)
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
When reassembling, fix the
fan motor lead wire to the
clamps to avoid contact with
the outdoor fan.
(R5568)