6

Technical Data

Hardware
Power supply
10 to 30 Vdc
Display
64,8 mm x 13,9 mm (2.551 x 0.547 in.)
1 line, 16 characters
Power consumption
AMC: 5 VA
Peripheral devices: using the PSU-60
Connectors
Pluggable screw connectors
2020-01 | V02 |
Integrated Microcontroller (32 bit, 30 MHz)
SRAM (256 kB)
Serial EEPROM
RTC (real time clock)
Pluggable Compact Flash card
Battery for SRAM and RTC
DIL switch for host settings (address and protocol mode)
Host interfaces
Ethernet 10/100 Mbit/s
RS-485 2-wire or 4-wire
Transfer rate: 38,4 kBit/s,
even parity, 7 bit, 1 stop bit,
RS-232
Transfer rate: 38,4 kBit/s
no parity, 8 bit, 1 stop bit
Four Wiegand interfaces for up to four card readers
(Output rating: 280 mA)
Eight relay outputs
maximum ratings (wet and dry):
switching voltage: 30 Vdc
switching current: 1,25 A
operating ratings (wet and dry):
1,25 A @ 30 Vdc
2 A @ 12 Vdc
1,5 A @ 24 Vdc
Eight analog inputs with tamper detection; only connect dry contacts
RS-485 extension interface:
Transfer rate: 9,6 kBit/s,
no parity, 8 bit, 2 stop bit
Tamper contact for external enclosures
up to 55 VA
constant load: 25 VA