Daikin GQI-Eco Series Service Manual page 79

R-410a 50hz
Table of Contents

Advertisement

ESIE15-13B
Level
Setting Code Function
1e
1
Unit of temperature
2
"Away from Home
function"
After being activated
below/above the
temperature set in the main
menu (see setting 1b-a),
the "Away from Home
function" switches on the
interior unit and the system
runs without setpoint until
the temperature is once
again within the safe
range. (Heating 5°C - 10°C
/cooling 35°C - 40°C)
Only for master units in the
system (if necessary,
consider setting 22-9)
4
Weekly timer
5
Clock display options
6
Sequence timer
a
Sensor calibration of
remote controller sensor in
the master remote
controller
b
Sensor calibration of
remote controller sensor in
the slave remote controller
Field Setting
Setting
Description
Remote controller setting (BRC1E)
01
°C
02
Optional choice of °C or °F
in "Extended functions"
menu option
01
Not available
02
Available for heating mode
03
Available for cooling mode
04
Available for heating and
cooling mode
01
Weekly timer is not
available
02
Weekly timer is available
01
24-hour display
02
You can choose between
24-hour or 12-hour display
in the "Extended functions"
menu option
01
Sequence timer is not
available
02
Sequence timer is
available
01
-3 K
02
-2.5 K
03
-2 K
04
-1.5 K
05
-1 K
06
-0.5 K
07
±0 K
08
+0.5 K
09
+1 K
01
-3 K
02
-2.5 K
03
-2 K
04
-1.5 K
05
-1 K
06
-0.5 K
07
±0 K
08
+0.5 K
09
+1 K
Field Setting from Remote Controller
Info
1x RETURN -> Extended
functions -> Unit of
temperature
To activate the Away from
Home function, press right
arrow for 5 seconds.
In the display you will see
To deactivate, press right
arrow again for 5 seconds.
If the sequence timer is
also deactivated under 1e-
6, the "Timer settings"
menu option disappears
1x RETURN -> Timer
adjustment -> Weekly timer
1x RETURN -> Extended
functions -> Time display
If the weekly timer is also
deactivated under 1e-4,
the "Timer settings" menu
option disappears
1x RETURN -> Timer
adjustment -> Sequence
timer
As from BRC1E software
ver.04.00.03
As from BRC1E software
ver.04.00.03