Download Print this page

Braun 9 SERIES Manual page 33

Type 5790
Hide thumbs Also See for 9 SERIES:

Advertisement

Installing the Clean&Charge Station (see fig. D)
• Press the lift button (13) at the rear side of the Clean&Charge Station to lift up the
housing.
• Hold the cleaning cartridge (17) down on a flat, stable surface (e.g. table).
• Carefully remove the lid from the cartridge.
• Slide the cartridge from the rear side into the base of the station until it snaps into
place.
• Slowly close the housing by pushing it down until it locks.
• Connect the station to an electrical outlet by snapping the special cord set (10) into
the power socket (12).
Charging the shaver in the Clean&Charge Station (see fig. D)
Insert the shaver head with the front showing and released head lock into the cleaning
station. Important: The shaver needs to be dry and free from any foam or soap
residue!
The contacts (7) on the back of the shaver need to align with the contacts (14) in the
station. Push the shaver in the correct position. A beep sound confirms that the shaver
sits properly in the station. Charging will start automatically.
Cleaning the shaver (see fig. D)
When the cleaning indicator
Clean&Charge Station, as described above and press the start button (16).
If status light (15b) does not shine (Clean&Charge Station switches to stand-by after
ca. 10 minutes), press start button twice. Otherwise cleaning will not start. For best
shaving results, we recommend cleaning after each shave.
The cleaning process consists of several cycles, in which cleaning fluid is flushed
through the shaver head. The cleaning time takes up to 3 minutes, followed by an
active drying phase of about 40 minutes, during which a fan is running.
Afterwards charging will resume, which is indicated in the shaver display. When the
shaver is fully charged the display turns off.
Removing the shaver from the Clean&Charge Station (see fig. E)
Hold the Clean&Charge Station with one hand and tilt the shaver slightly to the front to
release it.
Cleaning Cartridge / Replacement (see fig. F)
When the level indicator
cartridge is sufficient for about 3 more cycles. When the level indicator blinks red, the
cartridge needs to be replaced (about every 3 weeks when used daily).
After having pressed the lift button (13) to open the housing, wait for a few seconds
before removing the used cartridge to avoid any dripping. Before discarding the used
cartridge, make sure to close the openings using the lid of the new cartridge, since
the used cartridge will contain contaminated cleaning solution.
lights up in the shaver display, insert the shaver into the
(15a) lights up permanently red, the remaining fluid in the
33

Advertisement

loading

This manual is also suitable for:

9250cc