15
Passage under sewing foot
.06.12
Rule
1. When the automatic presser foot lift is activated, the clearance between the sewing
foot and needle plate should be should be 7 mm.
2. When the hand lever is raised, the clearance between the sewing foot and needle plate
should be should be 5 mm.
Fig. 15 - 13
O Adjust the solenoid 1 ( screw 2 ) according to rule 1.
O Raise the hand lever and place the adjustment gauge 3 (order no. 61-111 639-73) under
the sewing foot according to rule 2.
O Move the presser bar lifting lever 4 so that it touches the lift piece 5.
1
2
3
Make sure that the needle is positioned in the middle of the needle foot.
Adjustment
4
5
19