(2) Replacing 24VDC Input Power Fail Alert Fuse F2
・As for the cause, the abnormal voltage input is thought.
Confirm the input voltage of interface unit J11 terminal stand ➂ ➃.
Exchange fuses after confirming it is rating DC24V(DC21.5 ~31.5V).
Still, when the fuse is blown, because defects of the interface unit CQD-2083, the power supply CBD-1811,
the operation unit CCK-963, and wiring CFQ-9139, CFQ-9140, CFQ-9148, etc. are thought. Request the
repair.
(3) Replacing Built-in Printer Fuse F3
・As for the cause, in the case of the built-in printer, the over current of the external unit connected with printer
or Interface unit J13 ➀ ➁ is thought.
Remove the connecting cable of the external unit once. Still, when the fuse is blown, because defects of an
interface unit CQD-2083, a built-in printer H-7HPJD0001, and wiring CQD-9142, etc. are thought. Request
the repair.
6.7 Repair Parts
Parts name
Main Unit
TX/RX Unit
Power Supply Unit
I/F Unit
Operation Unit
LCD Panel ASSY
Printer
Screen plate
for JFE-680 printer
Screw Cap
Type
CDJ-2338-2A
CDJ-2338-2L
CMN-720-22
200kHz/200kHz as standard
CMN-720B25
200kHz/50kHz-A as option
CMN-720-25
200kHz/50kHz as option(Discontinued)
CMN-720B55
50kHz-A/50kHz-A as option
CMN-720-55
50kHz/50kHz as option(Discontinued)
CBD-1811
CQD-2083
CCK-963
CCN-464
H-7HPJD0003
BRBX05341
Closing board when there is no printer
BRBX05352
Decoration cap of front four corners screw
Remarks
6. Maintenance & Check 61