V-Check Spots - MSI Z87 MPOWER Instructions Manual

Hide thumbs Also See for Z87 MPOWER:
Table of Contents

Advertisement

V-Check Spots

These voltage check spots are for you to measure CPU and PCH voltages. To check
the voltage, please attach the positive lead of the multimeter to these spots and the
negative lead to any ground spot.
Spot
CPU_CORE3
CPU_CORE2
CPU_CORE1
CPU_VCOMP
CPU_VCCIO
PCH_VCCVRM
PCH_CORE
Getting Started
Description
CPU core3 voltage
CPU core2 voltage
CPU core1 voltage
CPU Vcomp voltage
IO voltage for CPU VCC
VRM voltage for PCH VCC
PCH core voltgae
1-32
CPU_CORE3
CPU_CORE2
CPU_CORE1
CPU_VCOMP
CPU_VCCIO
PCH_VCCVRM
PCH_CORE