1-5-8

PWBs

(1) Detaching and refitting the control PWB

Procedure
1. Remove the right cover (See page 1-5-4).
2. Remove the connectors form the control
PWB.
Simplex model: Twelve
Duplex model: Thirteen
3. Release the wires from the wire clamps.
Control PWB
Connectors
Simplex model: Eleven
Duplex model: Twelve
Wire clamps
A
Control PWB
A: Duplex model only
Figure 1-5-27
2H5/2HS
Connector
1-5-19