Memory channels may be grouped into as many as six convenient batches, for easy identification and selection. For ex-
ample, you might want to set aside memory groups for AM BC stations, shortwave broadcast stations, contest frequencies,
repeater frequencies, and PMS limits, or any other groupings you like.
Each memory group is capable of holding up to 19 or 20 memory channels (the Group size is fixed). When a memory
channel is grouped, the channel numbers change to correspond to the chart below:

Memory Group Assignment

1. Press the [ MENU ] button briefly, to enter the Menu
mode.
2. Rotate the ( VFO-A )[ SELECT ] knob to select Menu
item "036 GENE MEM GRP".
3. Rotate the ( VFO-B )[ SELECT ] knob to set this Menu
ENABLE
ENABLE
ENABLE" (the default setting is "DISABLE
ENABLE
item to "ENABLE
4. Press and hold in the [ MENU ] button for two seconds
to save the new setting and exit. Operation will now be
restricted to the six Memory Groups.
To cancel Memory Group operation, repeat steps (1)
through (4) above, choosing "DISABLE
A
DVICE
Note that for the PMS memory group, the PMS memories
P1L
P1L
P1L" through "P9U
P1L
P9U
P9U
P9U
P9U" will be so designated, to avoid con-
"P1L
fusion.

Choosing the Desired Memory Group

You may recall memories just within a particular Memory
Group, if desired.
1. Press the [ V/M ] button briefly, if necessary to enter the
Memory mode.
2. Press and hold the [ CLAR/GRP ] button for two sec-
onds. The [ CLAR/GRP ] button will glow yellow.
3. Rotate the [ CLAR ( VFO-B )] knob to select the desired
Memory Group.
4. Press and hold the [ BAND/MCH ] button. The [ BAND/
MCH ] button will glow yellow.
5. Rotate the [ CLAR ( VFO-B )] knob to select the desired
Memory Channel within the Selected Memory Group.
A
:
DVICE
If no channels have been assigned to a particular Memory
Group, you will not have access to that Group.
FT
5000 O
DX
PERATING
M
EMORY
DISABLE").
DISABLE
DISABLE
DISABLE
DISABLE
DISABLE
DISABLE" in step (3).
DISABLE
M
ANUAL
M
EMORY
G
ROUPS
M
EMORY
G
M
"OFF"
ROUP
EMORY
01 ~ 19
20 ~ 39
40 ~ 59
60 ~ 79
80 ~ 99
P-1L/1U ~ P-9L/9U
O
PERATION
( VFO-A )[ SELECT ] Knob
[ MENU ] Button
( VFO-B )[ SELECT ] Knob
C
N
HANNEL
UMBER
G
M
"ON"
ROUP
EMORY
1-01 ~ 1-19
2-01 ~ 2-20
3-01 ~ 3-20
4-01 ~ 4-20
5-01 ~ 5-20
P-1L/1U ~ P-9L/9U
[ CLAR/GRP ] Button
[ BAND/MCH ] Button
[ V/M ] Button
[ CLAR ( VFO-B )] Knob
Page 105

Advertisement

Table of Contents
loading

Table of Contents