Bar Code Symbology Settings; Code 39 - Wasp WCS 3900 Programming Manual

Table of Contents

Advertisement

Code 39 is variable length and is the most frequently used symbology in industrial bar code
systems today. It is extensively used within the Department of Defense (DOD). The principal
feature is to encode messages using the full alphanumeric character set. Standard Code 39
contains only 43 characters (0-9, A-Z, $, /, %, +, -, ., SPACE) and can be extended to a 128
character symbology (full ASCII) by combining one of the special characters (S, /, %, +) with a
letter (A-Z) to form the characters that are not present in the standard Code 39 symbology.
See page 5 for information on setting the minimum and maximum lengths.
Enable Code 39 *
Enable Code 39
Full ASCII *
Check Digit Do
Not Calculate *
Check Digit Calculate
But Do Not Send *
Minimum Length (1 *)
Code 39 Settings
Disable Code 39
Disable Code 39
Full ASCII
Check Digit Calculate
And Send
Maximum Length (48 *)
15
Chapter 5
*Default