Mitsubishi Electric Mr.Slim PLH-P3AAH.UK Technical & Service Manual page 15

Split-type, heat pump pair conditioners
Table of Contents

Advertisement

Item
Function
w1
Capacity
w1
Total input
Service Ref.
Power supply (phase, cycle,voltage)
Input
Running current w2
Starting current w2
External finish
Heat exchanger
Fan (drive) o No.
Fan motor output
Fan
Airflow (Lo-Mi2-Mi1-Hi)
External static pressure
Booster heater
Operation control & Thermostat
Sound level (Lo-Mi2-Mi1-Hi)
Unit drain pipe I.D.
W
Dimensions
D
H
Weight
Service Ref.
Power supply (phase, cycle, voltage)
Running current
Starting current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Heat exchanger
Fan (drive) o No.
Fan
Fan motor output
Airflow
Crankcase heater
Defrost method
Cooling
Sound level
Heating
W
Dimensions
D
H
Weight
Refrigerant
Charge
Oil (Model)
Liquid
Pipe size O.D.
Gas
Indoor side
Connection method
Outdoor side
Between the indoor &
Height difference
outdoor units
Piping length
NOTE:
1. Rating conditions (ISO T1)
Cooling : Indoor
: D.B. 27: (80˚F), W.B. 19: (66˚F)
Heating : Indoor : D.B. 20: (68˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Upper limit
D.B. 35: , W.B. 22.5 : D.B. 46:
Cooling
Lower limit
D.B. 19 :, W.B. 15:
Upper limit
D.B. 28:
Heating
Lower limit
D.B. 17:
All manuals and user guides at all-guides.com
Service Ref.
Btu/h
W
kW
w2
kW
A
A
kW
K / min (CFM)
Pa (mmAq)
kW
dB
mm (in.)
mm (in.)
mm (in.)
mm (in.)
kg (lbs.)
Single phase, 50Hz, 220–230–240V/ 3 phases, 50Hz, 380–400–415V (4wires)
A
A
kW
Internal thermostat, HP switch, Discharge thermo./ Thermal relay, HP switch, Discharge thermo.
kW
K / min (CFM)
W
dB
dB
mm (in.)
mm (in.)
mm (in.)
kg (lbs.)
kg (lbs.)
L
mm (in.)
mm (in.)
Outdoor
Outdoor
Indoor
Outdoor
D.B. -5:
D.B. 24: , W.B. 18:
D.B. -11: , W.B. -12:
15
PLH-P4AAH.UK / PLH-P4AAH
Cooling
33,100
9,700
3.69
PLH-P4AAH.UK / PLH-P4AAH
Single phase, 50Hz, 220–230–240V
0.26
1.25
2.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct) o 1
0.120
20-23-26-28 (705-810-920-990)
0 (direct blow)
<2.6>
Remote controller & built-in
33-36-39-41
32 (1-1/4)
UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)
UNIT : 298 (11-3/4)
PANEL : 30 (1-3/16)
UNIT : 32 (71)
PANEL : 5 (11)
PUH-P4VGAAH
UK / PUH-P4YGAA.UK
.
15.71/ 5.55
99/ 49
Munsell 5Y 7/1
Linear expansion valve
Hermetic
NE56VNJMT/ NE56YDKMT
2.7
Line start
Plate fin coil
Propeller (direct) o 2
0.070+0.070
85 (3,000)
38
Reverse cycle
51
53
900 (35-7/16)
330+20 (13+3/4)
1,260 (49-5/8)
96 (212)
R407C
4.0 (8.8)
1.3 (Ester) MEL56
9.52 (3/8)
19.05 (3/4)
Flared
Flared
Max. 50m
Max. 50m
: D.B. 35: (95˚F) W.B. 24: (75˚F)
: D.B. 7: (45˚F)
W.B. 6: (43˚F)
w1 : [ ] Shows the total rating.
w2 : < > Shows the only booster heater rating.
3. Above data based on indicated voltage
Indoor unit
Single phase 240V 50Hz
Outdoor unit
Single phase 240V 50Hz/ 3 phases 415V 50Hz
.UK
1
Heating
36,200 [43,300]
10,600 [12,700]
3.93 [6.03]
.UK
1
0.26 <2.60>
1.25 <10.83>
2.0 <10.83>
16.58/ 5.86