kW Model
PLA-RP·AA
PMH-P·BA
PEAD-RP·EA
PEAD-RP·GA
PKA-RP·GAL
PKA-RP·FAL
PCA-RP·GA
PCA-RP·HA
PSA-RP·GA
PUH-P35/50/60/71/100/125/140YGAA
PU-P35/50/60/71/100/125/140YGAA
CONTENTS
1. REFERENCE SERVICE MANUAL·············································2
2. SPECIFICATIONS ······································································3
3. OUTLINES AND DIMENSIONS················································36
4. WIRING DIAGRAM···································································58
5. REFRIGERANT SYSTEM DIAGRAM ······································70
6. PERFORMANCE CURVES ······················································73
7. CORRECTION FACTORS ························································75
8. AIR FLOW DATA ······································································76
9. NOISE CRITERION CURVES ··················································91
10. OPTIONAL PARTS ··································································105
R407C
PLH-P·AAH
PEHD-P·EAH
PKH-P·GALH
PKH-P·FALH
PCH-P·GAH
PSH-P·GAH
July 2005
No. OCS02

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PLA-RP-AA

  • Page 1: Table Of Contents

    SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS July 2005 No. OCS02 R407C TECHNICAL DATA BOOK <Indoor unit> [Model names] PLA-RP·AA PLH-P·AAH PMH-P·BA PEAD-RP·EA PEHD-P·EAH PEAD-RP·GA PKA-RP·GAL PKH-P·GALH PKA-RP·FAL PKH-P·FALH PCA-RP·GA PCH-P·GAH PCA-RP·HA PSA-RP·GA PSH-P·GAH <Outdoor unit> [Model names] PUH-P25/35/50/60/71/100VGAA PUH-P35/50/60/71/100/125/140YGAA PU-P35/50/60/71/100VGAA PU-P35/50/60/71/100/125/140YGAA...
  • Page 2: Puh-P25/35/50/60/71/100Vgaa

    REFERENCE SERVICE MANUAL For information on service refer to the service manual as follows. 1-1. INDOOR UNIT Model name Service Ref. Service Manual No. PLA-RP35/50/60/71AA PLA-RP35/50/60/71AA.UK OC335 PLA-RP100/125/140AA PLA-RP100/125/140AA.UK PLH-P35/50/60/71AAH PLH-P35/50/60/71AAH.UK PLH-P100/125/140AAH PLH-P100/125/140AAH.UK PMH-P25/35/50BA PMH-P25/35/50BA OC333 PCA-RP50/60/71/100/125/140GA PCA-RP50/60/71/100/125/140GA OC328 PCH-P50/60/71/100/125/140GAH PCH-P50/60/71/100/125/140GAH PCA-RP71/125HA PCA-RP71/125HA...
  • Page 3: Specifications

    SPECIFICATIONS 2-1. CEILING CASSETTE TYPE 2-1-1.HEAT PUMP (without HEATER) AND COOLING ONLY TYPE Model name Indoor unit PLA-RP35AA PLA-RP50AA Outdoor unit PUH-P35VGAA PUH-P35YGAA PUH-P50VGAA PUH-P50YGAA PU-P35VGAA PU-P35YGAA PU-P50VGAA PU-P50YGAA Cooling Capacity Btu/h 15,400 19,100 Total input 1.72 2.53 2.62 2.21 Energy label class 0.75 0.82...
  • Page 4 Model name Indoor unit PLA-RP60AA PLA-RP71AA Outdoor unit PUH-P60VGAA PUH-P60YGAA PUH-P71VGAA PUH-P71YGAA PU-P60VGAA PU-P60YGAA PU-P71VGAA PU-P71YGAA Cooling Capacity Btu/h 22,900 26,300 Total input 2.57 3.42 2.61 2.25 Energy label class 0.72 0.74 Heating * Capacity Btu/h 24,900 31,400 Total input 2.40 3.48 3.04...
  • Page 5 Model name Indoor unit PLA-RP100AA PLA-RP125AA PLA-RP140AA Outdoor unit PUH-P100VGAA PUH-P100YGAA PUH-P125YGAA PUH-P140YGAA PU-P100VGAA PU-P100YGAA PU-P125YGAA PU-P140YGAA Cooling Capacity Btu/h 32,800 45,400 48,500 13.3 14.2 Total input 3.68 5.09 5.90 2.61 2.61 2.41 Energy label class 0.78 0.72 0.69 Heating * Capacity Btu/h 35,800...
  • Page 6 2-1-2.HEAT PUMP (with HEATER) TYPE Model name Indoor unit PLH-P35AAH PLH-P50AAH Outdoor unit PUH-P35VGAA PUH-P35YGAA PUH-P50VGAA PUH-P50YGAA Cooling Capacity Btu/h 15,400 19,100 Total input 1.72 2.53 2.62 2.21 Energy label class 0.75 0.82 Heating Capacity Btu/h 16,900 21,700 4.95 6.35 Total input 1.70 2.20...
  • Page 7 Model name Indoor unit PLH-P60AAH PLH-P71AAH Outdoor unit PUH-P60VGAA PUH-P60YGAA PUH-P71VGAA PUH-P71YGAA Cooling Capacity Btu/h 22,900 26,300 Total input 2.57 3.42 2.61 2.25 Energy label class 0.72 0.74 Heating Capacity Btu/h 24,900 31,400 Total input 2.40 3.48 3.04 2.64 Energy label class Booster heater 1.93 1.93...
  • Page 8 Model name Indoor unit PLH-P100AAH PLH-P125AAH PLH-P140AAH Outdoor unit PUH-P100VGAA PUH-P100YGAA PUH-P125YGAA PUH-P140YGAA Cooling Capacity Btu/h 32,800 45,400 48,500 13.3 14.2 Total input 3.68 5.09 5.90 2.61 2.61 2.41 Energy label class 0.78 0.72 0.69 Heating Capacity Btu/h 35,800 53,200 58,000 10.5 15.6...
  • Page 9 2-1-3.HEAT PUMP (without HEATER) TYPE (PMH series) Model name Indoor unit PMH-P25BA PMH-P35BA Outdoor unit PUH-P25VGAA PUH-P35VGAA PUH-P35YGAA Cooling Capacity Btu/h 10,600 14,800 4.35 Total input 1.14 1.66 2.72 2.62 Energy label class 0.77 0.70 Heating Capacity Btu/h 11,400 16,900 3.35 4.95 Total input...
  • Page 10 Model name Indoor unit PMH-P50BA Outdoor unit PUH-P50VGAA PUH-P50YGAA Cooling Capacity Btu/h 18,300 5.35 Total input 2.31 2.32 Energy label class 0.67 Heating Capacity Btu/h 21,200 Total input 2.37 2.62 Energy label class Booster heater Power supply Phase Cycle Voltage Breaker size Indoor unit Air flow...
  • Page 11 2-2. CEILING-CONCEALED TYPE 2-2-1.HEAT PUMP (without HEATER) AND COOLING ONLY TYPE Model name Indoor unit PEAD-RP35EA PEAD-RP50EA Outdoor unit PUH-P35VGAA PUH-P35YGAA PUH-P50VGAA PUH-P50YGAA PU-P35VGAA PU-P35YGAA PU-P50VGAA PU-P50YGAA Cooling Capacity Btu/h 15,100 19,100 4.45 Total input 1.71 2.53 2.60 2.21 Energy label class 0.72 0.74 Heating *...
  • Page 12 Model name Indoor unit PEAD-RP60EA PEAD-RP71EA Outdoor unit PUH-P60VGAA PUH-P60YGAA PUH-P71VGAA PUH-P71YGAA PU-P60VGAA PU-P60YGAA PU-P71VGAA PU-P71YGAA Cooling Capacity Btu/h 22,500 25,900 Total input 2.65 3.35 2.49 2.27 Energy label class 0.71 0.78 Heating * Capacity Btu/h 24,300 30,800 7.15 9.05 Total input 2.36 3.18...
  • Page 13 Model name Indoor unit PEAD-RP100EA PEAD-RP125EA PEAD-RP140EA Outdoor unit PUH-P100VGAA PUH-P100YGAA PUH-P125YGAA PUH-P140YGAA PU-P100VGAA PU-P100YGAA PU-P125YGAA PU-P140YGAA Cooling Capacity Btu/h 32,700 41,600 47,700 12.2 Total input 3.83 4.87 5.81 2.51 2.51 2.41 Energy label class 0.75 0.74 0.74 Heating * Capacity Btu/h 35,100...
  • Page 14 Model name Indoor unit PEAD-RP60GA PEAD-RP71GA Outdoor unit PUH-P60VGAA PUH-P60YGAA PUH-P71VGAA PUH-P71YGAA PU-P60VGAA PU-P60YGAA PU-P71VGAA PU-P71YGAA Cooling Capacity Btu/h 22,500 25,900 Total input 2.74 3.35 2.41 2.27 Energy label class 0.72 0.76 Heating * Capacity Btu/h 24,300 30,800 7.15 9.05 Total input 2.50 3.18...
  • Page 15 Model name Indoor unit PEAD-RP100GA Outdoor unit PUH-P100VGAA PUH-P100YGAA PU-P100VGAA PU-P100YGAA Cooling Capacity Btu/h 32,700 Total input 3.68 2.61 Energy label class 0.75 Heating * Capacity Btu/h 35,100 10.3 Total input 3.67 2.81 Energy label class Booster heater Power supply Phase Cycle Voltage...
  • Page 16 2-2-2.HEAT PUMP (with HEATER) TYPE Model name Indoor unit PEHD-P35EAH PEHD-P50EAH Outdoor unit PUH-P35VGAA PUH-P35YGAA PUH-P50VGAA PUH-P50YGAA Cooling Capacity Btu/h 15,100 19,100 4.45 Total input 1.71 2.53 2.60 2.21 Energy label class 0.72 0.74 Heating Capacity Btu/h 16,500 21,400 4.85 Total input 1.73 2.20...
  • Page 17 Model name Indoor unit PEHD-P60EAH PEHD-P71EAH Outdoor unit PUH-P60VGAA PUH-P60YGAA PUH-P71VGAA PUH-P71YGAA Cooling Capacity Btu/h 22,500 25,900 Total input 2.65 3.35 2.49 2.27 Energy label class 0.71 0.78 Heating Capacity Btu/h 24,300 30,800 7.15 9.05 Total input 2.36 3.18 3.03 2.85 Energy label class Booster heater...
  • Page 18 Model name Indoor unit PEHD-P100EAH PEHD-P125EAH PEHD-P140EAH Outdoor unit PUH-P100VGAA PUH-P100YGAA PUH-P125YGAA PUH-P140YGAA Cooling Capacity Btu/h 32,700 41,600 47,700 12.2 Total input 3.83 4.87 5.81 2.51 2.51 2.41 Energy label class 0.75 0.74 0.74 Heating Capacity Btu/h 35,100 47,700 56,600 10.3 16.6 Total input...
  • Page 19 2-3. WALL-MOUNTED TYPE 2-3-1.HEAT PUMP (without HEATER) AND COOLING ONLY TYPE Model name Indoor unit PKA-RP35GAL PKA-RP50GAL Outdoor unit PUH-P35VGAA PUH-P35YGAA PUH-P50VGAA PUH-P50YGAA PU-P35VGAA PU-P35YGAA PU-P50VGAA PU-P50YGAA Cooling Capacity Btu/h 15,100 18,300 4.45 5.35 Total input 1.70 2.33 2.62 2.30 Energy label class 0.77 0.70...
  • Page 20 Model name Indoor unit PKA-RP60FAL PKA-RP71FAL Outdoor unit PUH-P60VGAA PUH-P60YGAA PUH-P71VGAA PUH-P71YGAA PU-P60VGAA PU-P60YGAA PU-P71VGAA PU-P71YGAA Cooling Capacity Btu/h 22,000 26,800 6.45 7.85 Total input 2.65 3.43 2.43 2.29 Energy label class 0.80 0.74 Heating * Capacity Btu/h 25,100 32,100 7.35 Total input 2.63...
  • Page 21 Model name Indoor unit PKA-RP100FAL Outdoor unit PUH-P100VGAA PUH-P100YGAA PU-P100VGAA PU-P100YGAA Cooling Capacity Btu/h 32,100 Total input 3.59 2.62 Energy label class 0.76 Heating * Capacity Btu/h 36,800 10.8 Total input 3.77 2.86 Energy label class Booster heater Power supply Phase Cycle Voltage...
  • Page 22 2-3-2.HEAT PUMP (with HEATER) TYPE Model name Indoor unit PKH-P35GALH PKH-P50GALH Outdoor unit PUH-P35VGAA PUH-P35YGAA PUH-P50VGAA PUH-P50YGAA Cooling Capacity Btu/h 15,100 18,300 4.45 5.35 Total input 1.70 2.33 2.62 2.30 Energy label class 0.77 0.70 Heating Capacity Btu/h 16,900 21,200 4.95 Total input 1.79...
  • Page 23 Model name Indoor unit PKH-P60FALH PKH-P71FALH Outdoor unit PUH-P60VGAA PUH-P60YGAA PUH-P71VGAA PUH-P71YGAA Cooling Capacity Btu/h 22,000 26,800 6.45 7.85 Total input 2.65 3.43 2.43 2.29 Energy label class 0.80 0.74 Heating Capacity Btu/h 25,100 32,100 7.35 Total input 2.63 3.61 2.79 2.60 Energy label class...
  • Page 24 Model name Indoor unit PKH-P100FALH Outdoor unit PUH-P100VGAA PUH-P100YGAA Cooling Capacity Btu/h 32,100 Total input 3.59 2.62 Energy label class 0.76 Heating Capacity Btu/h 36,800 10.8 Total input 3.77 2.86 Energy label class Booster heater 2.20 Power supply Phase Cycle Voltage Breaker size Power supply...
  • Page 25 2-4. CEILING-SUSPENDED TYPE 2-4-1.HEAT PUMP (without HEATER) AND COOLING ONLY TYPE Model name Indoor unit PCA-RP50GA PCA-RP60GA Outdoor unit PUH-P50VGAA PUH-P50YGAA PUH-P60VGAA PUH-P60YGAA PU-P50VGAA PU-P50YGAA PU-P60VGAA PU-P60YGAA Cooling Capacity Btu/h 18,300 22,500 5.35 Total input 2.35 2.62 2.28 2.52 Energy label class 0.72 0.75 Heating *...
  • Page 26 Model name Indoor unit PCA-RP71GA PCA-RP100GA Outdoor unit PUH-P71VGAA PUH-P71YGAA PUH-P100VGAA PUH-P100YGAA PU-P71VGAA PU-P71YGAA PU-P100VGAA PU-P100YGAA Cooling Capacity Btu/h 25,400 32,800 7.45 Total input 3.37 3.62 2.21 2.65 Energy label class 0.73 0.76 Heating * Capacity Btu/h 31,200 36,200 9.15 10.6 Total input 3.48...
  • Page 27 Model name Indoor unit PCA-RP125GA PCA-RP140GA Outdoor unit PUH-P125YGAA PUH-P140YGAA PU-P125YGAA PU-P140YGAA Cooling Capacity Btu/h 42,000 48,500 12.3 14.2 Total input 4.91 5.89 2.51 2.41 Energy label class 0.77 0.74 Heating * Capacity Btu/h 50,500 58,000 14.8 17.0 Total input 5.11 6.24 2.90...
  • Page 28 Model name Indoor unit PCA-RP71HA PCA-RP125HA Outdoor unit PUH-P71VGAA PUH-P71YGAA PUH-P125YGAA PU-P71VGAA PU-P71YGAA PU-P125YGAA Cooling Capacity Btu/h 25,600 44,400 13.0 Total input 3.36 4.90 2.23 2.65 Energy label class 0.72 0.72 Heating * Capacity Btu/h 31,400 54,600 16.0 Total input 3.41 4.98 2.70...
  • Page 29 2-4-2.HEAT PUMP (with HEATER) TYPE Model name Indoor unit PCH-P50GAH PCH-P60GAH Outdoor unit PUH-P50VGAA PUH-P50YGAA PUH-P60VGAA PUH-P60YGAA Cooling Capacity Btu/h 18,300 22,500 5.35 Total input 2.35 2.62 2.28 2.52 Energy label class 0.72 0.75 Heating Capacity Btu/h 21,200 24,700 7.25 Total input 2.36 2.66...
  • Page 30 Model name Indoor unit PCH-P71GAH PCH-P100GAH Outdoor unit PUH-P71VGAA PUH-P71YGAA PUH-P100VGAA PUH-P100YGAA Cooling Capacity Btu/h 25,400 32,800 7.45 Total input 3.37 3.62 2.21 2.65 Energy label class 0.73 0.76 Heating Capacity Btu/h 31,200 36,200 9.15 10.6 Total input 3.48 3.81 2.63 2.78 Energy label class...
  • Page 31 Model name Indoor unit PCH-P125GAH PCH-P140GAH Outdoor unit PUH-P125YGAA PUH-P140YGAA Cooling Capacity Btu/h 42,000 48,500 12.3 14.2 Total input 4.91 5.89 2.51 2.41 Energy label class 0.77 0.74 Heating Capacity Btu/h 50,500 58,000 14.8 17.0 Total input 5.11 6.24 2.90 2.72 Energy label class Booster heater...
  • Page 32: Floor Standing Type

    2-5. FLOOR STANDING TYPE 2-5-1.HEAT PUMP (without HEATER) AND COOLING ONLY TYPE Model name Indoor unit PSA-RP71GA PSA-RP100GA Outdoor unit PUH-P71VGAA PUH-P71YGAA PUH-P100VGAA PUH-P100YGAA PU-P71VGAA PU-P71YGAA PU-P100VGAA PU-P100YGAA Cooling Capacity Btu/h 25,900 32,800 Total input 3.39 3.75 2.24 2.56 Energy label class 0.72 0.72 Heating *...
  • Page 33 Model name Indoor unit PSA-RP125GA PSA-RP140GA Outdoor unit PUH-P125YGAA PUH-P140YGAA PU-P125YGAA PU-P140YGAA Cooling Capacity Btu/h 42,000 47,400 12.3 13.9 Total input 5.03 5.76 2.45 2.41 Energy label class 0.74 0.69 Heating * Capacity Btu/h 49,500 58,000 14.5 17.0 Total input 5.32 6.08 2.73...
  • Page 34 2-5-2.HEAT PUMP (with HEATER) TYPE Model name Indoor unit PSH-P71GAH PSH-P100GAH Outdoor unit PUH-P71VGAA PUH-P71YGAA PUH-P100VGAA PUH-P100YGAA Cooling Capacity Btu/h 25,900 32,800 Total input 3.39 3.75 2.24 2.56 Energy label class 0.72 0.72 Heating Capacity Btu/h 31,600 36,700 9.25 10.75 Total input 3.47 3.86...
  • Page 35 Model name Indoor unit PSH-P125GAH PSH-P140GAH Outdoor unit PUH-P125YGAA PUH-P140YGAA Cooling Capacity Btu/h 42,000 47,400 12.3 13.9 Total input 5.03 5.76 2.45 2.41 Energy label class 0.74 0.69 Heating Capacity Btu/h 49,500 58,000 14.5 17.0 Total input 5.32 6.08 2.73 2.80 Energy label class Booster heater...
  • Page 36: Outlines And Dimensions

    OUTLINES AND DIMENSIONS INDOOR UNIT Unit : mm PLA-RP35AA PLA-RP50AA PLA-RP60AA PLA-RP71AA PLA-RP100AA PLA-RP125AA PLA-RP140AA PLH-P35AAH PLH-P50AAH PLH-P60AAH PLH-P71AAH PLH-P100AAH PLH-P125AAH PLH-P140AAH Ceiling hole 20 - 45 860 - 910 20 - 45 Branch duct hole Fresh air intake (Cut out hole) Suspension bolt pitch 90 100 100 90 Branch...
  • Page 37 PMH-P25BA PMH-P35BA PMH-P50BA Unit : mm...
  • Page 38 PEAD-RP35EA PEAD-RP50EA PEAD-RP60EA Unit : mm Model R410A Outdoor unit : 6.35 w R410A Outdoor unit : 12.7 w RP35,50 R407C Outdoor unit : 9.52 R407C Outdoor unit : 15.88 Outdoor unit (SUZ) : 6.35 15.88 RP60 1012 1070 1044 R407C Outdoor unit : 9.52 w w Setting at shipment Service space:500 or more...
  • Page 39 PEHD-P35EAH PEHD-P50EAH PEHD-P60EAH Unit : mm Service space:500 or more 10-[3(P35, 50) 12-[3(P60) 50~150 Model Access door P35,50 1012 1070 1044 Lifting bolt hole (14o22) Refrigerant piping flare connection (liquid [9.52 copper tube):HP Refrigerant piping flare connection (gas [15.88 copper tube):LP Drain R1(External thread) Electrical parts box Electric Heater...
  • Page 40 PEAD-RP60GA Unit : mm PEAD-RP71GA PEAD-RP100GA Model Outdoor unit(SUZ) : 6.35 15.88 RP60 1125 1090 1050 1012 Other outdoor unit : 9.52 w 1050 RP71 1125 1090 1012 9.52 15.88 R410A Outdoor unit : 15.88 w RP100 1365 1330 1290 1252 1080 9.52...
  • Page 41 PKA-RP35GAL PKA-RP50GAL Unit : mm PKH-P35GALH PKH-P50GALH...
  • Page 42 PKA-RP60FAL PKA-RP71FAL Unit : mm PKH-P60FALH PKH-P71FALH Display section Emergency switch(Heat) Receiving section Emergency switch(Cool) Defrosting Initial heating lamp Power lamp Front Right side 1400 Left side Knock out hole for right piping 1090 Air intake Refrigerant pipe. Drain pipe Terminal block for indoor/outdoor connecting line Liquid pipe Knock out hole for...
  • Page 43 PKA-RP100FAL Unit : mm PKH-P100FALH Display section Emergency switch(Heat) Emergency switch(Cool) Receiving section Defrosting Initial heating lamp Power lamp Front Knock out hole for right piping Right side Left side 1680 1370 Air intake Knock out hole for left piping Terminal block for indoor/outdoor connecting line Liquid pipe Terminal block for heater (PKH only)
  • Page 44 PCA-RP50GA Unit : mm PCH-P50GAH NOTES: 1. Use M10 or W3/8 screws for anchor bolt. 2. When optional drain lift-up mechanism is installed, always provide upward piping for refrigerant piping. 933 (suspension bolt pitch) Electrical box liquid 1000 (Drainage) Air outlet Air intake 1 Drainage pipe connection (26mm I.D.) 2 Drainage pipe connection (for the left arrangement)
  • Page 45 PCA-RP60GA PCA-RP71GA Unit : mm PCH-P60GAH PCH-P71GAH NOTES: 1. Use M10 or W3/8 screws for anchor bolt. 2. When optional drain lift-up mechanism is installed, always provide upward piping for refrigerant piping. 1240 (suspension bolt pitch) 1290 Electrical box 1214 (liquid) 1310 (5/8F gas)
  • Page 46 PCA-RP100GA Unit : mm PCH-P100GAH NOTES: 1. Use M10 or W3/8 screws for anchor bolt. 2. When optional drain lift-up mechanism is installed, always provide upward piping for refrigerant piping. 1240 (suspension bolt pitch) Electrical box 1214 (3/8F liquid) 1310 (5/8F, 3/4F gas) (Drainage) Air outlet...
  • Page 47 PCA-RP125GA PCA-RP140GA Unit : mm PCH-P125GAH PCH-P140GAH NOTES: 1. Use M10 or W3/8 screws for anchor bolt. 2. When optional drain lift-up mechanism is installed, always provide upward piping for refrigerant piping. 1547(suspension bolt pitch) Electrical box 1524 (3/8F liquid) 1620 (5/8F, 3/4F gas) (Drainage)
  • Page 48 PCA-RP71HA Unit : mm...
  • Page 49 PCA-RP125HA Unit : mm...
  • Page 50 PSA-RP71GA Unit : mm PSH-P71GAH...
  • Page 51 PSA-RP100GA PSA-RP125GA PSA-RP140GA Unit : mm PSH-P100GAH PSH-P125GAH PSH-P140GAH...
  • Page 52 OUTDOOR UNIT Unit : mm PUH-P25VGAA PUH-P35VGAA PUH-P35YGAA PU-P35VGAA PU-P35YGAA...
  • Page 53 PUH-P50VGAA Unit : mm PUH-P50YGAA PUH-P60VGAA PUH-P60YGAA PUH-P71VGAA PUH-P71YGAA PU-P50VGAA PU-P50YGAA PU-P60VGAA PU-P60YGAA PU-P71VGAA PU-P71YGAA...
  • Page 54 PUH-P100VGAA Unit : mm PUH-P100YGAA PU-P100VGAA PU-P100YGAA...
  • Page 55 PUH-P125YGAA Unit : mm PUH-P140YGAA PU-P125YGAA PU-P140YGAA...
  • Page 56 Unit : mm WIRED REMOTE CONTROLLER...
  • Page 57 Unit : mm WIRELESS REMOTE CONTROLLER...
  • Page 58: Wiring Diagram

    WIRING DIAGRAM PLA-RP35AA PLA-RP50AA PLA-RP60AA PLA-RP71AA PLA-RP100AA PLA-RP125AA PLA-RP140AA PLH-P35AAH PLH-P50AAH PLH-P60AAH PLH-P71AAH PLH-P100AAH PLH-P125AAH PLH-P140AAH [LEGEND] SYMBOL NAME SYMBOL NAME SYMBOL NAME INDOOR POWER BOARD FAN MOTOR WIRELESS REMOTE CONTROLLER BOARD INDOOR CONTROLLER BOARD VANE MOTOR RECEIVING UNIT FUSE FUSE(T6.3AL250V) DEW PREVENTION HEATER BUZZER...
  • Page 59 PMH-P25BA PMH-P35BA PMH-P50BA [LEGEND] NOTES: SYMBOL NAME INDOOR CONTROLLER BOARD 1.Since the outdoor side electric wiring may change be sure CN2L CONNECTOR(LOSSNAY) to check the outdoor unit electric wiring for servicing. CN32 CONNECTOR(REMOTE SWITCH) 2.Indoor and outdoor connecting wires are made with polarities, CN41 CONNECTOR(HA TERMINAL-A) make wiring matching terminal numbers (S1, S2, S3).
  • Page 60 PEAD-RP35EA PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA PEAD-RP125EA PEAD-RP140EA...
  • Page 61 PEHD-P35EAH PEHD-P50EAH PEHD-P60EAH PEHD-P71EAH PEHD-P100EAH PEHD-P125EAH PEHD-P140EAH...
  • Page 62 PEAD-P60GA PEAD-P71GA PEAD-P100GA...
  • Page 63 PKA-RP35GAL PKA-RP50GAL PKH-P35GALH PKH-P50GALH CNDK CN2S (RED) (WHT) w1 (Fig.1) POWER DC13.1V SUPPLY ~(1PHASE) 230V 50Hz GRN/YLW OUTDOOR UNIT POWER POWER OUTDOOR VANE 1 3 5 CNDK UNIT CN6V ( WHT ) INDOOR/OUTDOOR (RED) (ORN) POWER ( GRN ) COMMUNICATION CN2D(WHT) POWER INDOOR/OUTDOOR...
  • Page 64 PKA-RP60FAL PKA-RP71FAL PKA-RP100FAL PKA-P60FALH PKA-P71FALH PKA-P100FALH SYMBOL NAME SYMBOL NAME SYMBOL NAME INDOOR POWER BOARD CAPACITOR(FAN MOTOR) WIRELESS REMOTE CONTROLLER BOARD INDOOR CONTROLLER BOARD FAN MOTOR RECEIVING UNIT FUSE FUSE(T6.3AL250V) VANE MOTOR BUZZER TERMINAL BLOCK (HEATER) wPKH-P.FALH VARISTOR LED1 LED(RUN INDICATOR ) models only or option for PKA-RP.FAL models.
  • Page 65 PCA-RP50GA PCA-RP60GA PCA-RP71GA PCA-RP100GA PCA-RP125GA PCA-RP140GA PCH-P50GAH PCH-P60GAH PCH-P71GAH PCH-P100GAH PCH-P125GAH PCH-P140GAH SYMBOL NAME SYMBOL NAME SYMBOL NAME INDOOR POWER BOARD FAN MOTOR WIRELESS REMOTE CONTROLLER BOARD(OPTION) INDOOR CONTROLLER BOARD VANE MOTOR RECEIVING UNIT FUSE FUSE (T6.3AL250V) BUZZER DRAIN-UP MACHINE (OPTION) LED1 LED(RUN INDICATOR) VARISTOR...
  • Page 66 PCA-RP71HA PCA-RP125HA [ LEGEND ] SYMBOL NAME SYMBOL NAME P. B INDOOR POWER BOARD MF1, MF2 FAN MOTOR I. B INDOOR CONTROLLER BOARD C1, C2 CAPACITOR(FAN MOTOR) FUSE FUSE (T6.3AL250V) DEW PREVENTION HEATER VARISTOR TERMINAL BLOCK(INDOOR UNIT POWER (OPTION)) CN2L CONNECTOR (LOSSNAY) CN32 CONNECTOR (REMOTE SWITCH)
  • Page 67 PSA-RP71GA PSA-RP100GA PSA-RP125GA PSA-RP140GA PSH-P71GAH PSH-P100GAH PSH-P125GAH PSH-P140GAH SYMBOL NAME SYMBOL NAME SYMBOL NAME INDOOR POWER BOARD SWITCH (MODEL SELECTION) See Table 1. CAPACITOR (FAN MOTOR) SWITCH (CAPACITY CODE) See Table 2. FAN MOTOR INDOOR CONTROLLER BOARD FUSE FUSE (T6.3AL250V) LOUVER MOTOR SWITCH (EMERGENCY OPERATION) VARISTOR...
  • Page 68 PUH-P25VGAA PUH-P35VGAA PUH-P50VGAA PUH-P60VGAA PUH-P71VGAA PUH-P100VGAA PU-P35VGAA PU-P50VGAA PU-P60VGAA PU-P71VGAA PU-P100VGAA SYMBOL NAME SYMBOL NAME COMPRESSOR (INNER THERMOSTAT) OUTDOOR CONTROLLER BOARD FAN MOTOR (INNER THERMOSTAT) FUSE1 (O.B) FUSE (6.3A) THERMISTOR LIQUID TEMP FUSE2 (O.B) FUSE (6.3A) DISCHARGE TEMP FUSE3 (O.B) FUSE (6.3A) COND.
  • Page 69 PUH-P35YGAA PUH-P50YGAA PUH-P60YGAA PUH-P71YGAA PUH-P100YGAA PUH-P125YGAA PUH-P140YGAA PU-P35YGAA PU-P50YGAA PU-P60YGAA PU-P71YGAA PU-P100YGAA PU-P125YGAA PU-P140YGAA SYMBOL NAME SYMBOL NAME COMPRESSOR OUTDOOR CONTROLLER BOARD FAN MOTOR (INNER THERMOSTAT) FUSE1 (O.B) FUSE (6.3A) THERMISTOR LIQUID TEMP FUSE2 (O.B) FUSE (6.3A) DISCHARGE TEMP FUSE3 (O.B) FUSE (6.3A) COND.
  • Page 70: Refrigerant System Diagram

    REFRIGERANT SYSTEM DIAGRAM 5.1 INDOOR UNIT PLA-RP•AA PLH-P•AAH PMH-P•BA PEAD-RP•EA PEHD-P•EAH PEAD-RP•GA PKA-RP•GAL PKH-P•GALH PKA-RP•FAL PKH-P•FALH PCA-RP•GA PCH-P•GAH PCA-RP•HA PSA-RP•GA PSH-P•GAH Strainer(#50) Heat exchanger Refrigerant GAS pipe connection (Flare) Thermistor TH5 (Cond./Eva. temperature) Refrigerant flow in cooling Refrigerant flow in heating Refrigerant LIQUID pipe connection (Flare) Distributor...
  • Page 71 5.2 OUTDOOR UNIT PUH-P25VGAA PUH-P35VGAA PUH-P50VGAA PUH-P60VGAA PUH-P71VGAA PUH-P35YGAA PUH-P50YGAA PUH-P60YGAA PUH-P71YGAA <4-way valve solenoid coil> Heating : ON High pressure Ball valve protect switch Cooling : OFF 4-way valve Outdoor heat exchanger (#50) Refrigerant GAS pipe Strainer Thermistor P25···12.7A({1/2") (TH6) P35~P71···15.88A({5/8") Service...
  • Page 72 PU-P35VGAA PU-P50VGAA PU-P60VGAA PU-P71VGAA PU-P35YGAA PU-P50YGAA PU-P60YGAA PU-P71YGAA High pressure Ball valve protect switch Outdoor heat exchanger (#50) Strainer Thermistor Refrigerant GAS pipe (TH6) 15.88A({5/8") Service Thermistor Service port (TH3) port Thermistor(TH4) Distributor Accumulator with strainer Compressor (#100) (#100) Strainer Strainer Refrigerant LIQUID pipe 9.52A({3/8")
  • Page 73: Performance Curves

    PERFORMANCE CURVES Cooling performance curve(50Hz) INDOOR W.B.(°C) INDOOR W.B.(°C) OUTDOOR D.B.(°C)
  • Page 74 Heating performance curve(50Hz) Correcting the capacity line influenced by frosting Not correcting the capactiy line influenced by frosting INDOOR D.B.(°C) INDOOR D.B.(°C) -12 -10 OUTDOOR W.B.(°C)
  • Page 75: Correction Factors

    CORRECTION FACTORS Cooling capacity correction factors Refrigerant piping length (one way) Outdoor unit PUH-P25VGAA 1.00 0.993 0.984 0.978 0.969 0.961 — — — — PU(H)-P35VGAA 1.00 0.993 0.984 0.978 0.969 0.961 0.956 0.948 — — PU(H)-P35YGAA PU(H)-P50VGAA 1.00 0.993 0.984 0.978 0.969 0.961...
  • Page 76: Air Flow Data

    AIR FLOW DATA 8-1. OUTLET AIR SPEED AND COVERAGE RANGE PLA-RP35AA PLA-RP50AA PLA-RP60AA PLA-RP71AA PLA-RP100AA PLA-RP125AA PLA-RP140AA PLH-P35AAH PLH-P50AAH PLH-P60AAH PLH-P71AAH PLH-P100AAH PLH-P125AAH PLH-P140AAH Air flow /min. Air speed m/sec. Coverage range PMH-P35A PMH-P25BA PMH-P50BA Air flow /min 10.0 11.0 Air speed m/sec Coverage range...
  • Page 77 8-2. PLA-RP•AA, PLH-P•AAH 8-2-1. FRESH AIR INTAKE AMOUNT...
  • Page 78 8-2-2. BRANCH DUCT (Installation at site)
  • Page 79 Branch duct air flow rate/static pressure characteristics PLA-RP35AA PLH-P35AAH 4-way air flow (horizontal vane) Rectangular duct 4-way air flow (horizontal vane) Round duct 3-way air flow (horizontal vane) Rectangular duct 3-way air flow (horizontal vane) Round duct 2-way air flow (horizontal vane) Rectangular duct 2-way air flow (horizontal vane) Round duct...
  • Page 80 PLA-RP50AA PLA-RP60AA PLH-P50AAH PLH-P60AAH 4-way air flow (horizontal vane) Rectangular duct 4-way air flow (horizontal vane) Round duct 3-way air flow (horizontal vane) Rectangular duct 3-way air flow (horizontal vane) Round duct 2-way air flow (horizontal vane) Rectangular duct 2-way air flow (horizontal vane) Round duct...
  • Page 81 PLA-RP71AA PLH-P71AAH 4-way air flow (horizontal vane) Rectangular duct 4-way air flow (horizontal vane) Round duct High High Air flow rate /min] Air flow rate /min] 3-way air flow (horizontal vane) Rectangular duct 3-way air flow (horizontal vane) Round duct High High Air flow rate...
  • Page 82 PLA-RP100AA PLH-P100AAH 4-way air flow (horizontal vane) Rectangular duct 4-way air flow (horizontal vane) Round duct High High Air flow rate /min] Air flow rate /min] 3-way air flow (horizontal vane) Rectangular duct 3-way air flow (horizontal vane) Round duct High High Air flow rate...
  • Page 83 PLA-RP125AA PLA-RP140AA PLH-P125AAH PLH-P140AAH 4-way air flow (horizontal vane) Rectangular duct 4-way air flow (horizontal vane) Round duct High High Air flow rate Air flow rate /min] /min] 3-way air flow (horizontal vane) Rectangular duct 3-way air flow (horizontal vane) Round duct High High Air flow rate...
  • Page 84 8-3.PMH-P•BA Air capacity taken from outside PMH-P·BA series are possible to be taken air from outside. When taking air from the outside, the duct fan can be used to. The air capacity should be 20% or less of the air flow SPEC(Hi). 288.5 4-{2.8 Flesh air intake hole...
  • Page 85 8-4. PEAD-RP·EA, GA, PEHD-P·EAH 8-4-1. FAN PERFORMANCE AND CORRECTED AIR FLOW PEAD-RP35EA PEHD-P35EAH Capacity Fan Performance <30Pa> Corrected Air Flow input Cooling 12 14 10 12 14 16 Air flow (CMM) Air Flow (CMM) Fan Performance <70Pa> Heating 10 12 14 16 18 Air flow (CMM) 10 12...
  • Page 86 PEAD-RP60EA PEHD-P60EAH Capacity Fan Performance <30Pa> Corrected Air Flow input Cooling 12 14 16 24 26 Air flow (CMM) 10 12 14 16 18 20 22 24 Air Flow (CMM) Heating Fan Performance <70Pa> 12 14 16 22 24 Air flow (CMM) 10 12 14 16 18 20 22 24 26 Air Flow (CMM) PEAD-RP71EA PEHD-P71EAH...
  • Page 87 PEAD-RP100EA PEHD-P100EAH Fan performance <130Pa> Fan performance <70Pa> Recommended range Recommended range 26 28 30 32 34 36 38 40 24 26 28 30 32 34 36 38 Air flow (CMM) A i r fl ow (CM M) Heating Corrected Air Flow Capacity Input Cooling...
  • Page 88 PEAD-RP140EA PEHD-P140EAH Fan performance <70Pa> Fan performance <130Pa> Recommended range Recommended range 36 38 40 42 44 46 48 50 52 36 38 40 42 44 46 48 50 Air flow (CMM) A i r flow (CMM ) Heating Corrected Air Flow Capacity Input Cooling...
  • Page 89 PEAD-RP60GA PEAD-RP71GA...
  • Page 90 PEAD-RP100GA...
  • Page 91: Noise Criterion Curves

    NOISE CRITERION CURVES PLA-RP35AA PLA-RP50AA NOTCH SPL(dB) LINE NOTCH SPL(dB) LINE High High PLH-P35AAH PLA-RP60AA Medium1 Medium1 PLH-P50AAH Medium2 Medium2 PLH-P60AAH NC-70 NC-70 NC-60 NC-60 NC-50 NC-50 NC-40 NC-40 NC-30 NC-30 APPROXIMATE APPROXIMATE THRESHOLD OF THRESHOLD OF HEARING FOR HEARING FOR NC-20 NC-20 CONTINUOUS...
  • Page 92 PLA-RP125AA PLA-RP140AA NOTCH SPL(dB) LINE NOTCH SPL(dB) LINE High High PLH-P125AAH PLH-P140AAH Medium1 Medium1 Medium2 Medium2 NC-70 NC-70 NC-60 NC-60 NC-50 NC-50 NC-40 NC-40 NC-30 NC-30 APPROXIMATE APPROXIMATE THRESHOLD OF THRESHOLD OF HEARING FOR HEARING FOR NC-20 NC-20 CONTINUOUS CONTINUOUS NOISE NOISE 1000...
  • Page 93 PMH-P25BA PMH-P35BA SPL(dB) LINE SPL(dB) LINE NOTCH NOTCH High High Medium1 Medium1 Medium2 Medium2 NC-70 NC-70 NC-60 NC-60 NC-50 NC-50 NC-40 NC-40 NC-30 NC-30 APPROXIMATE THRESHOLD OF APPROXIMATE THRESHOLD OF HEARING FOR NC-20 NC-20 HEARING FOR CONTINUOUS CONTINUOUS NOISE NOISE 1000 2000 4000...
  • Page 94 PEHD-P35EAH PEHD-P35EAH (External static (External static pressure 30Pa) pressure 70Pa) PEAD-RP35EA PEAD-RP35EA High High NC60 NC60 NC50 NC50 NC40 NC40 NC30 NC30 NC20 NC20 Approximate minimum Approximate minimum audible limit on audible limit on continuous noise continuous noise 1000 2000 4000 8000 1000...
  • Page 96 PKA-RP35GAL NOTCH SPL(dB) LINE PKA-RP50GAL High Medium1 PKH-P35GALH Medium2 PKH-P50GALH NC-70 NC-60 NC-50 NC-40 NC-30 APPROXIMATE TERESHOLD OF HEARING FOR NC-20 CONTINUOUS NOISE 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz UNIT WALL MICROPHONE...
  • Page 97 PKA-RP60FAL PKA-RP100FAL NOTCH SPL(dB) LINE NOTCH SPL(dB) LINE High High PKA-RP71FAL PKH-P100FALH PKH-P60FALH PKH-P71FALH NC-70 NC-70 NC-60 NC-60 NC-50 NC-50 NC-40 NC-40 NC-30 NC-30 APPROXIMATE APPROXIMATE TERESHOLD OF TERESHOLD OF HEARING FOR HEARING FOR NC-20 NC-20 CONTINUOUS CONTINUOUS NOISE NOISE 1000 2000 4000...
  • Page 98 PCA-RP60GA PCA-RP50GA NOTCH SPL(dB) LINE SPL(dB) LINE NOTCH High High PCA-RP71GA PCH-P50GAH Medium1 Medium1 PCH-P60GAH Medium2 Medium2 PCH-P71GAH NC-70 NC-70 NC-60 NC-60 NC-50 NC-50 NC-40 NC-40 NC-30 NC-30 APPROXIMATE APPROXIMATE THRESHOLD OF THRESHOLD OF HEARING FOR HEARING FOR NC-20 NC-20 CONTINUOUS CONTINUOUS NOISE...
  • Page 99 PCA-RP140GA NOTCH SPL(dB) LINE High PCH-P140GAH Medium1 Medium2 NC-70 NC-60 NC-50 NC-40 NC-30 APPROXIMATE THRESHOLD OF HEARING FOR NC-20 CONTINUOUS NOISE 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz ceiling unit about 1.4m MICROPHONE...
  • Page 100 PCA-RP125HA PCA-RP71HA NOTCH SPL(dB) LINE NOTCH SPL(dB) LINE High High NC-70 NC-70 NC-60 NC-60 NC-50 NC-50 NC-40 NC-40 NC-30 NC-30 APPROXIMATE APPROXIMATE TERESHOLD OF TERESHOLD OF HEARING FOR HEARING FOR NC-20 NC-20 CONTINUOUS CONTINUOUS NOISE NOISE 1000 2000 4000 8000 1000 2000 4000...
  • Page 101 PSA-RP71GA PSA-RP100GA SPL(dB) LINE NOTCH SPL(dB) LINE NOTCH High High PSH-P71GAH PSH-P100GAH NC-70 NC-70 NC-60 NC-60 NC-50 NC-50 NC-40 NC-40 NC-30 NC-30 APPROXIMATE APPROXIMATE HERESHOLD OF HERESHOLD OF REARING FOR REARING FOR NC-20 NC-20 CONTINUOUS CONTINUOUS NOISE NOISE 1000 2000 4000 8000 1000...
  • Page 102 PSA-RP140GA NOTCH SPL(dB) LINE High PSH-P140GAH NC-70 NC-60 NC-50 NC-40 NC-30 APPROXIMATE HERESHOLD OF REARING FOR NC-20 CONTINUOUS NOISE 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz MICROPHONE unit floor about 1.4m...
  • Page 103 MICROPHONE UNIT GROUND PUH-P25VGAA PUH-P35VGAA SPL(dB) LINE MODE SPL(dB) LINE MODE COOLING PUH-P35YGAA COOLING HEATING HEATING PU-P35VGAA PU-P35YGAA NC-70 NC-70 NC-60 NC-60 NC-50 NC-50 NC-40 NC-40 NC-30 NC-30 APPROXIMATE APPROXIMATE THRESHOLD OF THRESHOLD OF HEARING FOR HEARING FOR NC-20 NC-20 CONTINUOUS CONTINUOUS NOISE...
  • Page 104 PUH-P71VGAA PUH-P100VGAA SPL(dB) LINE SPL(dB) MODE MODE LINE PUH-P71YGAA PUH-P100YGAA COOLING COOLING HEATING PU-P71VGAA HEATING PU-P100VGAA PU-P71YGAA PU-P100YGAA NC-70 NC-70 NC-60 NC-60 NC-50 NC-50 NC-40 NC-40 NC-30 NC-30 APPROXIMATE APPROXIMATE THRESHOLD OF THRESHOLD OF HEARING FOR HEARING FOR NC-20 NC-20 CONTINUOUS CONTINUOUS NOISE...
  • Page 105: Optional Parts

    OPTIONAL PARTS 10-1. Indoor unit Part Name Model Name Applicable model Remote sensor PAC-SE41TS-E Remote operation adapter PAC-SF40RM-E All models Remote on/off adapter PAC-SE55RA-E Multi-functional casement PAC-SG03TM-E High-efficiency filter element PAC-SG01KF-E (PAC-SG03TM-E is needed.) PLA-RP·AA Grille·Wireless remote controller PLP-6AALM PLH-P·AAH Grille·Wired remote controller PLP-6AAMD Space panel...
  • Page 106 (Triple 25:25:50) SDT-112SA-E PU(H)-P140 HEAD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN CCopyright 2005 MITSUBISHI ELECTRIC ENGINEERING CO., LTD. New publication, effective Jul. 2005. Distributed in Jul. 2005 No.OCS02 PDF 8 Specifications subject to change without notice.

Table of Contents