SWING Temperature: This model does
not allow for SWING temperature adjust-
ment. This model utilizes thermostatic
fl ame modulation that will modulation
the main fl ame based on the difference
between room temperature and set tem-
perature (see example below).
Important - factory SWING TEMPERA-
TURE setting is 2 degrees. The thermo-
static fl ame modulation feature will not
allow this SWING to be changed.
EXAMPLE:
Set Temperature
Room Temp.
74F
73F
72F
Set Temperature (72)
71F (or less)
Pilot Method: Continuous/Standing Pilot
only (Intermittent Pilot Ignition (IPI)/
Spark-to-Pilot not allowed).
Pilot fl ame will remain ON when Main
Flame Cycles ON and OFF.
Manual Flame Adjustment while in
THERMOSTAT mode: If Flame-A is
manually adjusted while in thermostat
mode, it will override the automatic
fl ame setting until the fl ame cycles off,
then back ON thermostatically; when
the fl ame cycles ON again, automatic
fl ame adjustment will resume. Automatic
fl ame adjustment will also resume if the
operational mode is cycled out of, then
back into THERMOSTAT mode or if the
SET temperature is changed.
THERMOSTAT OFF LCD Displays:
MODE Zone: THERMO and OFF is
displayed
ROOM TEMP Zone: Measured tempera-
ture is displayed
SET TEMP Zone: SET TEMP is dis-
played
TIME/PROG Zone: Current day indicator
and current time is displayed
FLAME Zone: Blank
THERMOSTAT ON LCD Displays:
900719-00B
OPERATION
Continued
• MODE Zone: THERMO and ON are
displayed
• ROOM TEMP Zone: Measured tempera-
ture is displayed
• SET TEMP Zone: SET TEMP is dis-
played
• TIME/PROG Zone: Current day indicator
and current time is displayed
• FLAME Zone: A Flame Icon and fl ame
setting level number is displayed
Thermostat Disable Feature
The Thermostat Mode (described above)
Flame Level
may be disabled for applications where a
OFF
thermostat is not allowed or undesirable.
Level 1
When Thermostat Mode is Disabled:
Level 2
• The Modes of operation will cycle be-
Level 3
tween MANUAL ON and MANUAL OFF
(omitting THERMO).
• Program Operation (described below) is
also disabled.
• The SET TEMP zone will be blank.
• The room temperature will still be mea-
sured & displayed in the ROOM TEMP
Zone.
• The TIME/PROG zone will continue to
display the Clock and Day of week, but
none of the icons associated with Pro-
gram Mode will be displayed.
To disable or re-enable the Thermostat,
the transmitter must be in MANUAL
OFF Mode, then touch and hold the
SET TEMP Zone and the DOWN Button
simultaneously for 10- seconds. The
LCD screen will go blank except either
THERMO and OFF or THERMO and
ON will fl ash 3-times (0.5-seconds OFF,
0.5-seconds ON) to indicate the change
has been made.
DAY AND TIME DISPLAY
The current day of week and time of
day will be continuously displayed in the
TIME/PROG Zone (except during Setup
operations).
The day of week will be displayed as
one of the following: S, M, T, W, T, F, S
The time of day will be in 12-hour AM,
12-hour PM format. Midnight will be
displayed as 12:00am.
Day/Time Setup:
1. Press and hold the MODE Zone for 5
seconds to enter Day/Time Setup.