Section 7: Control Panel Startup / Testing; Control Panel Interface; Using The Control Panel Interface; Control Panel Setup - Generac Power Systems G007144 Installation Manuallines

50 hz air-cooled generator sets
Hide thumbs Also See for G007144:
Table of Contents

Advertisement

Section 7: Control Panel Startup / Testing

Control Panel Interface

See
Figure
7-1. The control panel interface (A) is located
under the lid of the enclosure. Verify both left and right
side locks are unlocked before attempting to lift lid. Open
lid as directed in
Opening The
The 7.5A fuse is located beneath the rubber cover (B) to
the right of the control panel.
Figure 7-1. Generator Set Control Panel

Using the Control Panel Interface

See
Figure 7-1
for button locations.
Button
Description of Operation
Activates fully automatic system operation. Allows
unit to automatically start and exercise generator
set according to exercise timer (see
AUTO (C)
Exercise
Timer).
Green LED flashes when generator set is running
as a result of a mains power loss.
Cranks and starts generator set. Transfer to
standby power will not occur unless there is a
MANUAL
mains power failure.
(D)
Blue LED illuminates when generator set is run-
ning in MANUAL. LED flashes when generator set
is running in MANUAL and mains power is lost.
OFF
Shuts down engine and prevents automatic oper-
(E)
ation of unit.
ESCAPE
Serves as an exit or "go back" function while navi-
(F)
gating control panel menus.
ENTER
When pressed, indicates acceptance of a
(G)
selected setting or navigational menu option.
Installation Guidelines For 50 Hz Air-Cooled Generator Sets
Lid.
B
A
D
E
F
C
001798
Setting The

Control Panel Setup

Activation

To activate the generator set, go to
gen.com
and follow the instructions.
Activation is a simple, one-time process. The generator
set will not prompt to activate again once the unit is acti-
vated, even if the generator set battery, fuse, and battery
charge circuit (T1/T2) are disconnected.
NOTE: The generator set must be connected to the
home Wi-Fi network for automatic authentication to be
completed successfully. See Wi-Fi manual for more infor-
mation.
NOTE: If home Wi-Fi network is not available, follow
instructions on www.activategen.com.
Proceed as follows after activating generator set on-line:
1. The display interface will launch Install Wizard
upon first power-up of the generator set.
G
2. Follow on-screen instructions on the generator set
along with Quick Start Guide supplied with the unit
to connect generator set to home Wi-Fi network.
3. Wait for on-line authentication of generator set
activation through connected home Wi-Fi network.
4. Follow on-screen instructions to complete the
Install Wizard.
NOTE: See
Figure
message shown below, press ESC and then ENTER to
reset to Install Wizard.
NOT ACTIVATED!
XXX (H)
Figure 7-2. Not Activated Screen
NOTE: Generator set can only be placed in AUTO mode
after completing activation process.
IMPORTANT NOTE: Fuel selector knob must be set
to the correct fuel for generator set to function
correctly.
Control Panel Startup / Testing
www.activate-
7-2. If generator set screen shows
009102
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

G007244G007145G007245G007146G007246G0071890

Table of Contents