Standby Power Rating
60 kW
STANDARD EQUIPMENT
• All input connections in one single area
• High coolant temperature shutdown
• Low oil pressure shutdown
• Low coolant level automatic shutdown
• Overspeed automatic shutdown
• Crank timer
• Exercise timer
• Oil drain extension
• Cool flow radiator
• Closed coolant recovery system
• UV/Ozone resistant hoses
FEATURES
• Innovative design and fully prototype tested
• UL 2200 Listed
• Solid state frequency compensated voltage regulator
• Dynamic and static battery charger
• Sound attenuated acoustically designed enclosure
• Whisper-Test™ for low noise level exercise
• Acoustically designed engine cooling system
• High flow low noise factory engineered exhaust system
• State of the art control system with R-Series digital control panel
60 Hz
Liquid Cooled Gas Engine Generator Sets
COMMERCIAL SERIES
Whisper-Test™

Low Speed Exercise

63 dB(A) at 23 feet
Transfer Switch is sold separately
• Watertight state of the art electrical connectors
• Mainline circuit breaker
• Radiator drain extension
• Battery charge alternator
• 2 Amp static battery charger
• Battery and battery cables
• Battery rack
• Fan and belt guards
• Isochronous governor
• Flex fuel line pigtail
• Watertight electrical connectors
• Rodent proof construction
• High efficiency, low distortion Generac designed alternator
• Vibration isolated from mounting base
• Matching Generac transfer switches engineered and tested to
work as a system
• All components easily accessible for maintenance
• Electrostatically applied textured powder paint
GENERAC 3.0L ENGINE
Naturally Aspirated
Gaseous Fueled
UL 2200 Listed

Advertisement

loading

Summary of Contents for Generac Power Systems Whisper-Test COMMERCIAL SERIES

  • Page 1: Low Speed Exercise

    Standby Power Rating 60 kW STANDARD EQUIPMENT • All input connections in one single area • High coolant temperature shutdown • Low oil pressure shutdown • Low coolant level automatic shutdown • Overspeed automatic shutdown • Crank timer • Exercise timer •...
  • Page 2: Generator Specifications

    APPLICATION & ENGINEERING DATA GENERATOR SPECIFICATIONS TYPE ...Synchronous ROTOR INSULATION ... Class H STATOR INSULATION ... Class H TOTAL HARMONIC DISTORTION ...<5% TELEPHONE INTERFERENCE FACTOR (TIF) ... <50 ALTERNATOR OUTPUT LEADS 3 PHASE ...4 wire BEARINGS...Sealed Ball COUPLING ... Flexible Disc LOAD CAPACITY (STANDBY RATING) ...
  • Page 3 COMMERCIAL 60 kW OPERATING DATA KW RATING ENGINE SIZE GENERATOR OUTPUT VOLTAGE/KW - 60Hz 120/240V, single phase, 1.0 pf 120/208V, 3-phase, 0.8 pf 120/240V, 3-phase, 0.8 pf 277/480V, 3-phase, 0.8 pf GENERATOR LOCKED ROTOR KVA AVAILABLE @ VOLTAGE DIP OF 35% Single phase or 208V &...
  • Page 4 UNIT WEIGHT: Steel 1650 lbs., Aluminum 1513 lbs. ® GENERAC POWER SYSTEMS, INC. • P.O. BOX 297 • WHITEWATER, WI 53190 www.guardiangenerators.com Bulletin 0174660SBY / Printed in USA 06.07, 08.07 © 2007 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.

This manual is also suitable for: