Component Locations; Inverter Control Panel; Led Indicators; Rebus Status Led - Generac Power Systems PWRcell X7600 Series Owner's Manual

Hide thumbs Also See for PWRcell X7600 Series:
Table of Contents

Advertisement

Component Locations

A
B
Figure 2-4. Component Locations
A
Control panel
B
Intake filter
C
Exhaust vent

Inverter Control Panel

A
C
B
F
E
Figure 2-5. Inverter Control Panel
A
LCD display
B
Navigation keys
C

REbus status LED

D

Inverter LED

E
Safety Shutdown
F

Safety Shutdown LED

G

Internet LED

Owner's Manual for Generac PWRcell Inverter
See
Figure
the Generac PWRcell Inverter control panel. The inverter
control panel is used for adjusting system settings and for
interacting with devices.

LED Indicators

C
See
Figure 2-5
REbus Status LED
REbus Status LED (C) communicates REbus nanogrid
status through LED color.
Green – all devices are functioning normally and
are either generating power or ready to generate
power.
Yellow – no devices are connected or no devices
are enabled.
Red – one or more REbus device has a fault that
requires attention before operation will continue.
009656
NOTE: A red LED can also indicate a fault with the
REbus nanogrid itself. See display (A) for more
information about the specific fault detected.
Inverter LED
Inverter LED (D) communicates the status of the utility
grid and/or inverter through LED color and state.
Green – utility is connected and within normal
operational voltage and frequency.
Blinking green – system is in standby mode,
powering up, or initializing.
Yellow – utility grid is not within normal conditions,
but user intervention typically is not required. The
D
inverter will restart as soon as the utility grid
returns to normal conditions.
Red – a serious fault with the utility grid or inverter
has been detected and user attention is required
before the unit will resume operation. See display
(A) for more information about the specific fault
G
detected.
No light – the inverter is disabled or powered off.
Safety Shutdown LED
009894
Safety Shutdown LED (F) is illuminated when the system
is in Safety Shutdown mode. Safety Shutdown may be
initiated either from the Safety Shutdown button on the
unit or an externally-installed shutdown switch. See
Safety
Shutdown.
Internet LED
Internet LED (D) is illuminated when the inverter is
connected to a router and has an IP address. See
Ethernet
Configuration.
NOTE: A blue Internet LED does not mean that the
inverter has connected with the Generac server.
General Information
2-5. Generac PWRcell is controlled through
for LED locations.