For Furnace Purifiers:
Black Lead - Connect to Hot (L1) or EAC-1 when provided.
White Lead - Connect to Neutral (L2) or EAC-2 when provided.
Green/Ground Lead - Connect to Appliance Ground (Chassis).

START-UP and OPERATION

Checking Return Air Purifier Operation
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Before installing or servicing system, always turn off main power to
system. There may be more than one disconnect switch. Lock out and
tag switch with a suitable warning label.
1. Turn the HVAC system power on and adjust the thermostat or
System Control to activate the system fan.
2. Turn the Return Air Purifier power switch to ON position.
3. The green indicator light on the power supply door should
illuminate
(Fig.
17).
This green indicator light will illuminate when the Return Air Purifier
door is installed, the power switch is in the ON position AND the
furnace blower is running. The indicator will be OFF when the furnace
blower is not running.
NOTE: For information on the green indicator light status and error
conditions, See
Table 1
for status codes or
section Error and Status Codes.
Fig. 17 – Power Switch and Indicator
Control
When the Return Air Purifier is used with a Communicating Wall
Control, the Control can be configured to remind the homeowner when it
is time to change the Return Air Purifier cartridge. This maintenance
reminder can be based on either the TrueSense™ dirty filter algorithm or
time. The installer should use their discretion to select the most
appropriate option based on the initial system static pressure.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 2
for error codes in
POWER SWITCH
GREEN POWER-ON LED
A200504
7
Maximizing Performance
Maximum air purification performance is obtained when the furnace
blower is set for continuous operation on the thermostat or Control.

MAINTENANCE

The Return Air Purifier is designed to require minimal maintenance.
Maintenance is limited to the periodic replacement of the air purification
cartridge and inspection/brush cleaning of the ionization array.
Frequency of cartridge replacement and cleaning of the ionization array
may vary depending on ductwork design and local environmental
conditions, generally 6-9 months.
WARNING
!
FIRE HAZARD
Failure to follow this warning could result in personal injury or
equipment damage.
Use of non-factory approved filter cartridge will void the warranty and
may cause damage due to fire.
This equipment should be inspected frequently and collected dirt
removed regularly to prevent excessive accumulation that may result in
flash-over or fire damage.
To replace the Return Air Purifier filter cartridge,
complete the following steps:
Turn the heating and cooling system power off.
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Before installing or servicing system, always turn off main power to
system. There may be more than one disconnect switch. Lock out and
tag switch with a suitable warning label.
IMPORTANT: Use of any filter cartridge in the Return Air Purifier
other than the genuine replacement purifier cartridge listed in the table
below will likely result in poor performance and may constitute a safety
hazard. Do not use any third-party air filters in the Return Air Purifier.
PURIFIER MODEL
REPLACEMENT MEDIA CARTRIDGE
RGAP(A,B)XX1625
1. Open the return air grille cover.
2. Unlatch the unit and slowly lower the inner purifier unit. This will
disable the power.
3. Slide out the old cartridge and discard.
4. Install the new filter cartridge
IMPORTANT: Make sure the metal tabs on the leading edge of the
filter case are inserted first. They must not be visible after the filter is
installed. Follow the instructions printed on the filter cartridge
Otherwise, the unit will not operate properly.