Cleaning The Cold Water Inlet Filter; Cleaning The Air Intake Filter - Bosch Singular 4000 Installation Instructions Manual

Gas condensing combi boilers
Hide thumbs Also See for Singular 4000:
Table of Contents

Advertisement

Installation Instructions

16.2 Cleaning the Cold Water Inlet Filter

To clean the cold water inlet fi lter:
1. Drain the boiler. Refer to Section 16.1 " Draining the Boiler        " .
2. Remove the cold water inlet fi lter from the boiler.
Figure 98
3. Rinse the cold water inlet fi lter with clean running water.
4. Reinsert the cold water inlet fi lter.
5. Refi ll the boiler. Refer to " Draining the Boiler        " on page 60.

16.3 Cleaning the Air Intake Filter

To maintain the boiler properly, clean the air intake fi lter every 2–3 months. If the
air intake fi lter is clogged by dust or lint, the boiler will cease to operate or error can
occur.
To clean the air intake fi lter:
1. Press the
button to turn off the boiler.
2. Disconnect the power supply to the boiler.
3. Remove the boiler front cover by loosening the 2 Phillips screws securing it
to the case.
6 2 |
Figure 99
4. Remove the air intake fi lter located under the air intake connector.
Figure 100
5. Rinse the air intake fi lter with clean running water.
6. Dry the air intake fi lter completely.
7. Reinsert the air intake fi lter and replace the front cover.
Singular Combi Boiler - BTC 439003301 B (2021/07)