Stairs — Given Only Floor-to-Floor Rise
You're building a stairway with a total Rise of 9 Feet 11 Inches. Your
desired Riser height is 7-1/2 Inches and desired Tread width is 10
Inches. The desired Headroom is 6 Feet 8 Inches and Floor
Thickness 10 Inches*. Find all stair values, then calculate the Run.
*Note: Headroom and Floor Thickness are required to calculate the height of the stair-
well opening.
KEYSTROKE
1. Enter known Rise:
o o
9 f 1 1 i r
2. Recall (default) stored "desired" stair Riser height:
® s
3. Find Riser height, number of Risers, Riser Overage/Underage,
Tread width, number of Treads, Tread Overage/Underage, length of
stairwell opening, Stringer length and Angle of Incline. As a final
step, calculate the Run:
s
s
s
s
s
s
s
s
s
s
s*
*Continuous presses of s will also recall stored desired Riser height, Tread,
Headroom and Floor Thickness values.
96 — S
M
HEET
ETAL
/HVAC P
RO
C
ALC
Y 9
R-HT
STORED
R-HT 7-7/16
OPEN 10
STRG 15
FEET
INCL 36.64003°
RUN 12
RISE (
)
Y
STORED
DISPLAY
0.
11
FEET
INCH
7-1/2
INCH
INCH
RSRS 16.
R+/– 0
INCH
T-WD 10
INCH
TRDS 15.
T+/– 0
INCH
1
FEET
INCH
6-15/16
INCH
6
FEET
INCH
9
11
FEET
INCH