Finishing; Facing Material - Heat & Glo TRUE-36S-IFT Installation Manual

Hide thumbs Also See for TRUE-36S-IFT:
Table of Contents

Advertisement

10
10

Finishing

A. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or fi nishing materials must not interfere
with air fl ow through louvers, operation of louvers or
decorative fronts, or access for service.
• Facing and/or fi nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of decorative fronts and
louvers.
NOTICE: Surface temperatures around the appliance will
become warm while the appliance is in operation. Ensure
finishing materials used for all surfaces (floor, walls,
mantels, etc.) will withstand temperatures up to 190°F.
COMBUSTIBLE MATERIAL
0 IN.
0 in.
NON-COMBUSTIBLE
MODEL
in.
TRUE-36-IFT
61
TRUE-42-IFT
67
TRUE-50-IFT
75
Figure 10.1 Non-combustible Facing Diagram
46
Heat & Glo • TRUE-36-IFT, TRUE-42-IFT, TRUE-50-IFT Installation Manual • 2461-980 Rev. B • 2/17
0 IN.
A
B
BOARD
A
B
mm
in.
mm
1549
57-5/8
1464
1702
62-5/8
1591
1905
66-5/8
1692

Advertisement

Table of Contents
loading

Table of Contents