Carrier 40QSM009DS Service Manual page 115

Light commercial inverter side discharge cdu type
Table of Contents

Advertisement

3. IPM continuity check
Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital
tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
(+)Red
(-)Black
N
U
P
V
W
4: Pressure on Service Port
Cooling chart:
Indoor
(℃)
Temp.
(23.89)
BAR
70
BAR
75
BAR
80
PSI
70
PSI
75
PSI
80
MPA
70
MPA
75
MPA
80
Pressure (bar)
12.0
10.0
8.0
6.0
4.0
2.0
0.0
75 (23.89) 85 (29.44)
Normal resistance value
(Several MΩ)
COOLING MODE
Outdoor temp.
75
85
(29.44)
8.2
7.8
8.6
8.3
9.3
8.9
119
113
124
120
135
129
0.82
0.78
0.86
0.83
0.93
0.89
95
(35)
Digital tester
(+)Red
U
V
W
(+)Red
95
105
(35)
(40.56)
8.1
8.6
8.7
9.1
9.1
9.6
117
125
126
132
132
140
0.81
0.86
0.87
0.91
0.91
0.96
105
115
(40.56)
(46.11)
112
Normal resistance value
(-)Black
N
(Several MΩ)
115
(46.11)
10.1
10.7
11.2
147
155
162
1.01
1.07
1.12
70
75
80
Outdoor temp.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents