Timing Chart; Initialization - Epson Stylus 1500 Reference Manual

Epson stylus 1500: reference guide
Hide thumbs Also See for Stylus 1500:
Table of Contents

Advertisement

Note:
The column heading "Direction" refers to the direction of signal flow as
viewed from the printer.
"Return Pin" denotes the twisted-pair return pin to be connected at signal
ground level. For the interface wiring, be sure to use a twisted-pair cable for
each signal and to complete the connection on the return side.
All interface conditions are based on TTL level. Both the rise and fall times of
each signal must be less than 0.2 microseconds.
Data transfer must be carried out by observing the ACKNLG or BUSY
signal. Data transfer to this printer can be carried out only after receipt of
the ACKNLG signal or when the level of the BUSY signal is LOW.

Timing chart

BUSY
ACKNLG
DATA
STROBE
0.5 s (Min.)
Transition time (the rise and the fall) of every signal must be less than 0.2 s.

Initialization

The printer can be initialized (returned to a fixed set of conditions) in
these ways:
Hardware
initialization
Software
initialization
Control panel
initialization
0 s (Min.)
The printer is turned on.
The printer receives an INIT signal from the parallel
interface: pin 31 goes LOW
Software sends the ESC @ (initialize the printer)
command; the last panel settings are kept
Hold down the Pause button and the Alt button; the
last panel settings are kept
0 s (Min.)
5 s (Typ.)
Technical Specifications
B-13