REMOVING THE MEAT PROBE JACK

WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
CAUTION: When you work on the built-in
oven, be careful when handling the sheet metal
parts. Sharp edges may be present, and you
can cut yourself if you are not careful.
1.
Disconnect the electrical power to the
oven.
2.
Remove the racks from inside the oven.
Meat Probe Jack
3.
Remove the hex nut from the meat probe
jack.
4.
Pull the oven out of its mounting location
approximately 8˝, (see page 4-4 steps 1
through 3 for the procedure), so that you
can access the meat probe jack access
panel on the right side.
All manuals and user guides at all-guides.com
Meat Probe
Jack
Hex Nut
4-11
5.
Remove the meat probe jack access panel
from the right side of the unit. Use a pair of
small cutters to clip the bridge.
Right Side
6.
Push aside the insulation, pull the meat
probe jack out of the access hole, and
remove the star washer from the jack.
7.
Cut the wires near the lugs of the old meat
probe jack, then use two small wire nuts,
and splice the new jack to the oven wires.
Star Washer
Meat Probe Jack
REASSEMBLY NOTE: When you install the
new jack, be sure to place the star washer from
the old jack on the threaded end of the new
one. After you have installed the jack, mount
the access cover with two #8 x 1/4˝ screws.
Clip Bridge
Meat Probe
Jack
Access
Panel
Of Oven
Access Cover