Table 2 Electrical Specifications - Bard Q24H2-A Installation Instructions Manual

Hide thumbs Also See for Q24H2-A:
Table of Contents

Advertisement

No.
Rated
Field
MODEL
Volts &
Power
Phase
Circuits
Q24H2-A0Z
1
A05
230/208-1
1
A10
1 or 2
Q24H2-B0Z
1
B06
230/208-3
1
B09
1
Q24H2-C0Z
1
C06
460-3
1
C09
1
Q30H2-A0Z
1
A05
230/208-1
1
A10
1 or 2
Q30H2-B0Z
1
B06
1
230/208-3
B09
1
B12
1
Q30H2-C0Z
1
C06
1
460-3
C09
1
C12
1
Q36H2-A0Z
1
A05
1
230/208-1
A10
1 or 2
 A15
1 or 2
Q36H2-B0Z
1
B06
1
230/208-3
B09
1
 B15
1
Q36H2-C0Z
1
C06
1
460-3
C09
1
 C15
1
Q42H2-A0Z
1
A05
1
230/208-1
A10
1 or 2
 A15
1 or 2
Q42H2-B0Z
1
B06
1
230/208-3
B09
1
 B15
1
Q42H2-C0Z
1
C06
1
460-3
C09
1
 C15
1
Q48H2-A0Z
1
A05
1 or 2
230/208-1
A10
1 or 2
 A15
1 or 2
Q48H2-B0Z
1
B06
1
230/208-3
B09
1
 B15
1
Q48H2-C0Z
1
C06
1
460-3
C09
1
 C15
1
Q60H2-A0Z
1
A05
1 or 2
230/208-1
A10
1 or 2
 A15
1 or 2
Q60H2-B0Z
1
B09
230/208-3
1
 B15
1
Q60H2-C0Z
1
C09
460-3
1
 C15
1
 Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.
 Based on 75°C copper wire. All wiring must conform to the National Electrical Code and all local codes.
 These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest
revision), article 310 for power conductor sizing.
Caution: When more than one field power conductor circuit is run through one conduit, the conductors must be derated. Pay special
attention to note 8 of table 310 regarding Ampacity Adjustment Factors when more than three conductors are in a raceway.
 Maximum KW that can operate with heat pump on is 10KW. Other 5KW energizes during emergency heat only.
 Maximum KW that can operate with heat pump on is 9KW. Other 6KW energizes during emergency heat only.
TABLE 2
ELECTRICAL SPECIFICATIONS
Single Circuit
Maximum
Field
Minimum
External
Power
Circuit
Fuse or
Wire
Ampacity
Ckt. Brkr.
Size
22
30
10
47
50
8
72
80
4
17
20
12
35
35
8
44
45
8
10
15
14
19
20
12
23
25
10
25
35
8
50
50
8
75
80
4
18
25
10
37
40
8
45
45
8
55
60
6
12
15
14
21
25
10
25
25
10
30
30
10
31
45
8
56
60
6
81
90
4
83
90
4
25
30
10
43
50
8
52
60
6
53
60
6
12
15
14
21
25
10
26
30
10
27
30
10
34
50
8
59
60
6
84
90
4
84
90
4
25
35
8
43
50
8
52
60
6
53
60
6
13
15
14
22
25
10
26
30
10
27
30
10
38
50
8
63
70
6
88
90
3
88
90
3
29
40
8
47
50
8
56
60
6
56
60
6
15
20
12
24
25
10
28
30
10
28
30
10
45
60
8
70
90
4
95
100
3
95
100
3
31
45
8
58
60
6
58
60
6
17
25
10
31
35
8
31
35
8
 Minimum
 Maximum
Circuit
External Fuse
Ampacity
or Ckt. Breaker
Ground
Wire
Ckt. A
Ckt. B
Ckt. A
10
10
8
22
50
30
12
10
10
14
12
10
10
10
8
25
50
30
10
10
10
10
14
10
10
10
10
10
8
31
50
45
8
33
50
45
10
10
10
10
14
10
10
10
10
10
8
34
50
45
8
34
50
45
10
10
10
10
14
10
10
10
10
8
38
25
50
8
38
50
50
8
38
50
50
10
10
10
10
12
10
10
10
10
8
45
25
60
8
45
50
60
8
45
50
60
10
10
10
10
10
10
Dual Circuit
Field Power
Ground
Wire Size
Wire Size
Ckt. B
Ckt. A
Ckt. B
Ckt. A
50
10
8
10
50
10
8
10
50
8
8
10
50
8
8
10
50
8
8
10
50
8
8
10
25
8
10
10
50
8
8
10
50
8
8
10
25
8
10
10
50
8
8
10
50
8
8
10
Manual
2100-601B
Page
5 of 42
Ckt. B
10
10
10
10
10
10
10
10
10
10
10
10

Advertisement

Table of Contents
loading

Table of Contents