Viessmann Vitocrossal 200 Service Instructions For Contractors page 59

Gas condensing boiler with matrix radiant burner 6 bar
Hide thumbs Also See for Vitocrossal 200:
Table of Contents

Advertisement

Specification
(cont.)
Rated heating output
TF/TR = 50/30
TF/TR = 80/60
Flue gas parameters
*2
Temperature (at a return temper-
ature of 30 °C)
At rated heating output
At partial load
Temperature (at a return temper-
ature of 60 °C)
Mass flow rate (for natural gas)
At rated heating output
At partial load
Available draught
At the flue outlet
*3
Flue gas connection
Draught at the flue outlet
Product parameters according
to EnEV
Standard seasonal efficiency
[to DIN]
For heating system temperature
40/30 °C
For heating system temperature
75/60 °C
Standby loss qB,70
MatriX radiant burner
Burner type
Voltage
Frequency
Power consumption
Upper rated heating output
Lower rated heating output
Modulation range
Dimensions
Length
Total length
Length with burner hood
Width
Height
Total weight (with burner hood
and combination valve)
Calculation values for sizing the flue system to EN 13384, based on 10 % CO
*2
Flue gas temperatures as actual gross values at 20 °C combustion air temperature.
The details for partial load refer to an output of 33 % of the rated heating output. If the partial load differs (subject to burner
operating mode), calculate the flue gas mass flow rate accordingly.
If using the Vitocrossal 200 with moisture-resistant chimneys, the draught must be no more than 0 Pa.
*3
kW
29 - 87
38 - 115
kW
27 - 80
35 - 105
°C
45
°C
35
°C
75
kg/h
127
kg/h
42
Pa
70
mbar
0.7
DN
150
mm
160
Pa
70
mbar
0.7
%
Up to 98 (Hs) [gross cv] / 109 (Hi) [net cv]
%
Up to 96 (Hs) [gross cv] / 106 (Hi) [net cv]
%
0.6
VMA III-1 VMA III-2 VMA III-3 VMA III-4 VMA III-5
V
230
Hz
50
W
75
W
25
%
33-100
mm
450
mm
595
mm
510
mm
550
mm
480
kg
27.5
47 - 142
62 - 186
43 - 130
56 - 170
45
45
35
35
75
75
166
205
55
69
70
70
0.7
0.7
150
150
160
160
70
70
0.7
0.7
0.5
0.4
230
230
50
50
140
185
40
45
33-100
33-100
25-100
450
450
595
595
510
510
550
550
480
480
32
32.5
for natural gas
2
Specification
82 - 246
104 - 311
75 - 225
95 - 285
45
45
45
35
35
35
75
75
75
269
356
451
90
119
150
70
70
70
0.7
0.7
0.7
200
200
200
200
200
200
70
70
70
0.7
0.7
0.7
0.4
0.3
0.3
VMA III-6
230
230
230
50
50
50
270
330
385
45
50
55
33-100
33-100
450
450
450
595
595
595
510
510
510
550
550
550
480
480
480
33
33.5
35.5
59