User Information - Hussmann R3HV-WD-B Installation & Operation Manual

Refrigerated high volume wide straight or curved glass, service-self-service bakery merchandiser, combination service and self-service deli case with rear storage
Table of Contents

Advertisement

Stocking
Improper temperature and lighting will cause serious
product loss. Discoloration, dehydration and spoilage
can be controlled with proper use of the equipment and
handling of product. Product temperature should always
be maintained at a constant and proper temperature.
This means that from the time the product is received,
through storage, preparation and display, the temperature
of the product must be controlled to maximize life of the
product. Hussmann cases were not designed to "heat up"
or "cool down" product - but rather to maintain an item's
proper temperature for maximum shelf life. To achieve the
protection required always:
1. Minimize processing time to avoid damaging
temperature rise to the product. Product should be
at proper temperature.
2. Keep the air in and around the case area free
of foreign gasses and fumes or food will rapidly
deteriorate.
3. Maintain the display merchandisers temperature
controls as outlined in the refrigerator section of this
manual.
4. Do not place any product into these refrigerators
until all controls have been adjusted and they
are operating at the proper temperature. Allow
merchandiser to operate a minimum of 6 hours
before stocking with any product.
5. When stocking, never allow the product to extend
beyond the recommended load limit. Air discharge
and return air fl ow must be unobstructed at all
times to provide proper refrigeration.
6. Keep the service doors closed (when applicable).
Refrigeration performance will be seriously affected
if left open for a prolonged period of time.
7. Avoid the use of supplemental fl ood or spot lighting.
Display light intensity has been designed for
maximum visibility and product life at the factory.
The use of higher output LED lamps (H.O. and
V.H.O.), will shorten the shelf life of the product.
Evaporator Fans
The evaporator fans are located at the center front of these
merchandisers directly beneath the display pans. Should
fans or blades need servicing, always replace fan blades
with the raised embossed side of the blade TOWARD THE
MOTOR.
Copper Coils
The copper coils used in Hussmann merchandisers may
be repaired in the fi eld. Materials are available from local
refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.

8. User Information

Aluminum Coils
The aluminum coils should be replaced if damaged.
Non-Glare Glass (Optional)
The high optical clarity of this glass is possible due to
special coatings on the glass surface itself. To preserve this
coating and the optical clarity, keep the glass clean.
Water is the only solution recommended to be used to
clean the non-glare glass. The damage to the glass from
improper, caustic solutions is irreparable.
In addition to cleaning the glass with the recommended
product, there are precautions that should be taken when
working and cleaning the inside of the case.
Plexiglass and Acrylic Care
Improper cleaning not only accelerates the cleaning cycle
but also degrades the quality of this surface. Normal daily
buffi ng motions can generated static cling attracting dust
to the surface. Incorrect cleaning agents or cleaning cloths
can cause micro scratching of the surface, causing the
plastic to haze over time.
Cleaning
Hussmann recommends using a clean damp chamois, or a
paper towel marketed as dust and abrasive free with 210
Plastic Cleaner and Polish available by calling Sumner
Labs at 1-800-542-8656. Hard, rough cloths or paper towels
will scratch the acrylic and should not be used.
Antistatic Coatings
The product 210
only cleaning and polishing the Plexiglass surface, but also
providing anti-static and anti-fog capabilities. This product
also seals pores and provides a protective coating.
Tips and Troubleshooting
Before calling for service, check the following:
16
When cleaning the inside of the cases, we
recommend that the glass be fully opened and
covered to prevent to prevent solutions from
splashing onto the glass and ruining the coating on
the inside.
Only use a soft cloth and water (in a spray bottle) for
cleaning any glass or mirrored components. Be sure
to rinse and/or dry completely.
Never use hot water on cold glass surfaces!
It may shatter and cause serious injury! Allow
glass surfaces to warmed to room temperature.
®
has proven to be very effective in not
1. Check electrical power supply to the equipment for
connection.
2. Check fi xture loading. Overstocking case will affect
its proper operation.
3. If frost is collecting on fi xture and/or product, check
that no outside doors or windows are open allowing
®

Advertisement