Maintenance
Always recycle batteries at an official
recycling center in accordance with all
local laws and regulations.
Do not place tools or metallic objects on top of bat-
tery.
Remove all jewelry, including watches, rings, and
other metal objects.
Use tools with insulated handles.
If electrolyte contacts the skin, wash it off immedi-
ately with water.
If electrolyte contacts the eyes, immediately thor-
oughly flush with water and seek medical attention.
Wash down spilled electrolyte with an acid neutral-
izing agent. A common practice is to use a solution
of 454g (1 lb) bicarbonate of soda to 3.8 L (1 gal) of
water. Add bicarbonate of soda solution until evi-
dence of reaction (foaming) has ceased. Flush
resulting liquid with water and dry area completely.
DO NOT smoke when near battery.
DO NOT cause flame or spark in battery area.
Discharge static electricity from the body before
touching the battery by first touching a grounded
metal surface.
Battery should be regularly inspected per the
Schedule. Contact an IASD for assistance if necessary.

Inspecting the Battery

Proceed as follows to inspect battery:
1. Perform "To turn the generator set OFF" in
ator Set Enable/Disable
2. Remove front access panel and intake side panel
as described in
Remove Front Access Panel
Remove Intake Side
3. See
Figure
4-7. Disconnect white battery charger
cable.
Figure 4-7. Disconnecting Battery Charger Cable
34
ISO000228
Service
Gener-
Procedure.
Panel.
002389
4. See
Figure
for tightness and corrosion. Tighten and clean as
necessary.
Figure 4-8. Battery Cables
5. (Unsealed batteries only): Completely disconnect
battery. Check battery fluid level and, if necessary,
fill with distilled water only. DO NOT use tap water.
Have an IASD or a qualified service technician ver-
ify the state of charge and condition.
6. Connect battery cables and install intake side
panel and front access panel when inspection is
complete.
7. Perform "To turn the generator set back ON" in
Generator Set Enable/Disable
Always recycle batteries in accordance with local laws
and regulations. Contact your local solid waste collection
site or recycling facility to obtain information on local
recycling processes. For more information on battery
recycling, visit the Battery Council International website
at: http://batterycouncil.org.

Cleaning the Sediment Trap

The sediment trap removes contaminants (moisture and
and
fine particles) from gaseous fuels before they enter the
fuel regulator. Accumulated moisture and particles must
be emptied from the sediment trap per local codes and
guidelines.
Proceed as follows to clean sediment trap:
1. Perform all steps in
able
Procedure.
2. Remove intake side panel.
3. Turn generator set fuel supply off.
4. See
Figure
trap cap (A).
Owner's Manual for 50 Hz Air-Cooled Generator Sets
4-8. Inspect battery posts and cables
Procedure.
Generator Set Enable/Dis-
4-9. Unscrew and remove sediment
001832