Installing the C3K Switch
Guidelines for Installation in a 19-Inch Rack
The installation site must be within reach of the network cabling and meet the requirements listed
below:
•
Appropriate grounded power receptacles must be located within 152 cm (5 ft) of the location.
•
A temperature of between 5° C (41° F) and 50° C (122° F) must be maintained at the installation
site with fluctuations of less than 10° C (18° F) per hour.
Attaching Brackets and Installing in Rack
Proceed as follows to install the switch into a 19‐inch rack:
1.
Attach the rackmount brackets to the switch, as shown in Figure
mm flathead screws shipped with the switch.
Figure 2-6
1 Rackmount brackets
2-12 Hardware Installation
Note: To ensure proper ventilation and prevent overheating, leave a minimum clearance
space of 5.1 cm (2.0 in.) at the left, right, and rear of the switch.
Warning: Before rack-mounting the device, ensure that the rack can support it without
compromising stability. Otherwise, personal injury and/or equipment damage may result.
Advertencia: Antes de montar el equipo en el rack, asegurarse que el rack puede
soportar su peso sin comprometer su propia estabilidad, de otra forma, daño personal o
del equipo puede ocurrir.
Warnhinweis: Überzeugen Sie sich vor dem Einbau des Gerätes in das Rack von dessen
Stabilität, ansonsten könnten Personenschäden oder Schäden am Gerät die Folge sein.
Attaching the Rackmount Brackets
2 M3 x 6 mm flathead screws
2‐6, using the eight M3 x 6